FIRE EXTINGUISHER NOTES1CLASS ABC FIRE EXTINGUISHER: EXTINGUISHERS SHALL BE CONSPICUOUSLY LOCATED ANDREADILY ACCESSIBLE. THE TOP OF THE EXTINGUISHER SHALL NOT BE MORE THAN 5 FT. ABOVE THEFLOOR AND THE BOTTOM OF THE EXTINGUISHER SHALL NOT BE LESS THAN 4 INCHES ABOVE THEFLOOR. EXTINGUISHERS SHALL BE INSTALLED IN ACCORDANCE WITH CLASSIFICATION, RATING,AND DISTRIBUTION REQUIREMENTS OF NFPA 10. [NFPA 1: 13.6.1.2]2CLASS K FIRE EXTINGUISHER:CLASS K FIRE EXTINGUISHERS SHALL BE PROVIDED FOR HAZARDS WHERE THERE IS A POTENTIALFOR FIRES INVOLVING COMBUSTIBLE COOKING MEDIA. [NFPA 10:4.3.2]1. G.C. TO PROVIDE MIN. OF 1 FIRE EXTINGUISHER. G.C. TO VERIFY AND COORDINATE LOCATIONSANDQUANTITIES WITH LOCAL FIRE MARSHAL.2. PER IFC, THE MINIMUM IS A 2A0010BC EXTINGUISHER WITHIN 75' OF TRAVEL DISTANCE OF ALLAREAS.3. NFPA INSPECTION TAGS SHALL BE ATTACHED TO ALL FIRE EXTINGUISHERS.CODE INFORMATIONAPPLICABLE CODES:• BUILDING CODE:2019 CALIFORNIA BUILDING CODE• PLUMBING CODE:2019 CALIFORNIA PLUMBING CODE• MECHANICAL CODE:2019 CALIFORNIA MECHANICAL CODE• ELECTRICAL CODE:2019 CALIFORNIA ELECTRICAL CODE• FIRE CODE:2019 CALIFORNIA FIRE CODE• ENERGY CODE:2019 CALIFORNIA ENERGY CODE• ACCESSIBILITY CODE: 2019 CALIFORNIA BUILDING STANDARDS - TITLE 24• ASHRAE90.1 2007A.) CHAPTER 3: USE & OCCUPANCY CLASSIFICATION:• GROUP: A-2 (RESTAURANT)• AREA: 2,067 SQ. FT.• TYPE: IIB• REQUIRED FIRE-RESISTIVE RATINGS:B.) CHAPTER 6: TYPES OF CONSTRUCTION:BUILDING ELEMENTRATINGSTRUCTURAL FRAME0BEARING WALLS - EXTERIOR0BEARING WALLS - INTERIOR0NON-BEARING WALLS - EXTERIOR0NON-BEARING WALLS - INTERIOR0FLOOR CONSTRUCTION0ROOF CONSTRUCTION0• REQUIRED INTERIOR WALL & CEILING FINISH CLASSIFICATIONS:D.) CHAPTER 8: INTERIOR FINISHES:TYPE OF SPACEFINISH CLASSIFICATIONEXIT ENCLOSURES & EXIT PASSAGEWAYBCORRIDORSBROOMS & ENCLOSED SPACESC• MINIMUM NUMBER OF EXITS REQUIRED = 2 REQUIRED, 2 PROVIDED• MINIMUM EXIT WIDTH REQUIRED: 36"• MINIMUM EXIT WIDTH FOR OTHER EGRESS COMPONENTS = 13", 36" MINIMUM• MAXIMUM EXIT TRAVEL DISTANCE = 250'-0", 63'-11" PROVIDED• OCCUPANT LOAD CALCULATIONS:E.) CHAPTER 10: MEANS OF EGRESS:FUNCTION OF SPACEAREA OF SPACE FLOOR AREA / SQ.FT. OCCUPANT LOADPER OCCUPANTASSEMBLY - NON-FIXED SEATS UNCONCENTRATED 1,108 SQUARE FEET 1574ASSEMBLY - STANDING51 SQUARE FEET 510COMMERCIAL KITCHEN415 SQUARE FEET 2002RESTROOMS/HALLWAY/UNOCC./NOT CALCULATED 493 SQUARE FEET 00TOTAL2,067 SQUARE FEET -86• MALE OCCUPANT LOAD: (86 / 2 = 43) = 1 WATER CLOSET• FEMALE OCCUPANT LOAD: (86 / 2 = 43) = 2 WATER CLOSETS• PLUMBING FIXTURE COUNT CALCULATIONS: E.) 2019 CPC SECTION 422: PLUMBING FIXTURE REQUIREMENTS: FIXTURE TYPEWATER CLOSET1 MALE / 2 FEMALE REQUIRED, PROVIDED BY BASE BUILDING (WALMART)LAVATORY1 REQUIRED IN EACH, PROVIDED BY BASE BUILDING (WALMART)* 1 SERVICE SINK REQUIREDEGRESS PLAN KEYPATTERNDINING (FLEXIBLE)QUEUING (STANDING)KITCHEN (ACCESSORY)TOTALFUNCTION OF SPACETRANSITION STRIP SHLUTER RENO-RAMPEXISTING VINYL TILEQUARRY TILE FLOOR, QT-1QUARRY TILE FLOOR, QT-1EXISTING VINYL TILEEXISTING WALK-IN COOLER FLOOR TO BE PRESERVEDTRANSITION STRIP SHLUTER RENO-RAMPPATH #1: 63' -11" PATH #2: 63' -11"PATH #3: 44' -4" PATH #4: 44' -4"COMMON PATH: 31' -7"COMMON PATH: 28' -4"FIRE EXTINGUISHERS PER 2019 CFC.SURFACE MOUNT TYPE ABC AND K, MOUNT TOP AT 44" A.F.F COORDINATE LOCATIONS WITH FIRE MARSHALL12GC TO VERIFY 1-HR FIRE RATED WALLPATH #2PATH #1GC TO VERIFY 1-HR FIRE RATED WALLPATH #4PATH #3FRONT ENTRANCE TO WALMARTREAR DOOR6 7 '-4 " D IS T A N C E BE T W E E N E X IT S71'-1 " O V E R A L L D IA G O N A L D IS T A N C E TYP.3' - 0"BEVERAGE COUNTER AND CONTROLS FOR BEVERAGE EQUIPMENT SHALL COMPLY WITH FIGURE 11B-308.3.2 OF THE 2019 CBCIt is the responsibility of the ConstructionManager/General Contractor and allSub-Contractors to verify all dimensions andaccept conditions of prior work by relatedtrades before proceeding with any work.DateDrawn ByScaleSeal:Project TitleProject AddressProject NumberDrawing Title and NumberMAIN OFFICE:1 HUNTINGTON QUADRANGLESUITE 2C03MELVILLE, NY 11747P: 631.226-7700 F: 631.226.7175Issued:Check ByOwner:AS SHOWNSTAFFCM© Copyright 2018: RGBK, INC.CharleysRobert Cheung2043 Limewood Drive,San Jose, CA 95132Stockton, CAWM15543223 E Hammer Ln,Stockton, CA 95212WM1554LIFE SAFETY AND FLOORFINISH PLANA0.107-22-2021SCALE: 1/8" = 1'-0"4Finish Floor PlanSCALE: 1/4" = 1'-0"5Egress PlanRev.No.DescriptionDateIssued for Permit08-23-2021