Laserfiche WebLink
Environmental Health Department <br />Time In: <br /> 9:40 am <br /> 9:04 am <br />Time Out: <br />Program Element: 3612 - PUBLIC POOL/SPA - ADDITIONAL <br />Telephone: (209) 957-6061 Owner/Operator: KATZAKIAN PROPERTY MANAGEMENT <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 4901 GROUSE RUN DR, STOCKTON 95207 <br />Date: 08/28/2023Name of Facility: QUAILBROOK COA <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #10 Disinfectant Residual MAJOR <br />OBSERVATIONS: Free chlorine is below 3 ppm. Adjust to 3 ppm to 10 ppm. Close spa until the corrections are made and <br />verified by this department. <br />CALCODE DESCRIPTION: Public pools, when open or in use, shall be disinfected continuously by approved chemicals and shall maintain <br />the following concentrations: 1.0 ppm to 10.0 ppm free chlorine without cyanuric acid, 2.0 ppm to 10.0 ppm free chlorine with cyanuric acid <br />or 2.0 ppm bromine. Spas, wading pools, and spray grounds shall maintain the following concentrations: 3.0 ppm to 10.0 ppm free <br />chlorine or 4.0 ppm bromine. (CCR 65529) <br /> #12 pH Level MAJOR <br />OBSERVATIONS: pH is below 7. Adjust to 7.2 to 7.8. Close spa until the corrections are made and verified by this <br />department. (REPEAT) <br />CALCODE DESCRIPTION: Pool operator shall maintain pH between 7.2 and 7.8. (CCR 65530) <br /> #3 Safety Signs <br />OBSERVATIONS: Safety sign is lacking spa hours and capacity. All safety signs shall be posted. Correct today. <br />(REPEAT) <br />CALCODE DESCRIPTION: Pool operator shall keep safety signs well maintained. (CCR 65535) Safety signs shall have clearly legible <br />letters or numbers not less than 4 inches high, unless otherwise specified. Safety signs shall be affixed to a wall, pole, gate, or similar <br />permanent structure in a location visible to all pool users, unless otherwise specified. (CBC 3120B) <br /> #9 Ladders and Handrails <br />OBSERVATIONS: One handrail was observed loose. Tighten handrail within one week. (REPEAT) <br />CALCODE DESCRIPTION: A means of entry and exit shall be provided at both the shallow and deep end of the pool. Ladders and <br />handrails shall be corrosion resistant and shall be rigidly installed. At least one handrail shall extend from the deck to not less than a point <br />above the top of the lowest step. Handrails shall be installed between 28 to 36 inches above the steps and deck. (CBC 3111B) Pool <br />operator shall keep ladders and handrails well maintained. (CCR 65535) <br />Page 1 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0002673 PR0360251 SC001 08/28/2023 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD