COMPLIANCE INFO_2023 RPT OF FACILITY INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MACARTHUR
>
30703
>
4400 - Solid Waste Program
>
PR0505006
>
COMPLIANCE INFO_2023 RPT OF FACILITY INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/1/2025 1:28:51 PM
Creation date
10/2/2023 2:45:35 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2023 RPT OF FACILITY INFO
RECORD_ID
PR0505006
PE
4445
FACILITY_ID
FA0006475
FACILITY_NAME
TRACY MATERIAL RECOVERY/TRANSF
STREET_NUMBER
30703
Direction
S
STREET_NAME
MACARTHUR
STREET_TYPE
DR
City
TRACY
Zip
95376
APN
25313019
CURRENT_STATUS
01
SITE_LOCATION
30703 S MACARTHUR DR
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\cfield
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
759
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
f) The project sponsor shall abide by the applicable.Airport Land Use Plan for Tracy Municipal <br /> Airport and the Federal Airport Administration Advisory Circular No: 150/5200-33B,Hazardous <br /> Wildlife Attractants On or Near Airports. <br /> 6) CITY OF TRACY—BUILDING DEPARTMENT(Staff Contact:Kevin Jorgensen,(209)831-6416) <br /> a) The inside turning radius for fire access roads should be a minimum of 27W". <br /> b) Provide a water source in terms of hydrants or tanks appropriately sized for fire-fighting <br /> operations. <br /> c) No Smoking signage is required. <br /> d) Secure the appropriate operational fire permits for a)combustible dust producing facilities if the <br /> C&D fines qualify as combustible dust b)combustible fibers c)private fire hydrants if used d) <br /> miscellaneous combustible storage e)waste handling and 0 wood products. <br /> e) For outdoor storage only noncombustible materials can be stored under high-voltage <br /> transmission lines. <br /> If there is combustible dust production,then the NFPA 664 standards will apply. <br /> g) Demonstrate on an expanded site plan where access roads begin and end. Figure A2 <br /> demonstrates a partial idea of such access. <br /> h) Where and what is the fuel source for the required material handling equipment?This VAII need <br /> to be demonstrated. <br /> Q Submit an emergency plan for monitoring,controlling and extinguishing spot fires for review <br /> and approval. <br /> j) Provide portable fire extinguishers rated 4A;60B;C on all vehicles and equipment. <br /> 7) SAN JOAQUIN VALLEY AIR POLLUTION CONTROL DISTRICT(Staff Contact: Mark Montelongo, <br /> (559)230-5905) <br /> a) The Districts Guidelines for Assessing and Mitigating Air Quality Impacts(GAMAQI)does not <br /> specifically identify a threshold of significance for PM10 emissions. However,the District <br /> recommends use of a 15 tons per year threshold as set by the New Source Review(NSR)Offset <br /> Requirements. Therefore the District recommends amending the MND and emissions <br /> assessments to reflect a 15 tons per year threshold of significance for PM10. Thresholds of <br /> significance for Reactive Organic Gas (ROG)and Oxides of Nitrogen(NOx).are also set in <br /> accordance with the NSR Offset Requirements. <br /> b) Currently the District is in the preliminary stages of developing a new draft rule(Draft Rule 4566) <br /> for Composting and Related Operations. The MRFITS Compost Emission Estimates <br /> assessment/methodology may need to be revised based on the outcome of the rule development <br /> process. <br /> c) The project includes an expansion of 29,400 square feet to an existing 47,200 square foot <br /> building,and an additional 10,500 square foot expansion to an existing <br /> maintenance/administration building. The MND doesn't quantify or characterize the expansions <br /> construction related emissions. The District recommends quantifying construction related <br /> emissions and assessing the projects potential impacts on air quality. <br /> Conditions of Approval -8- PA-0800005 <br />
The URL can be used to link to this page
Your browser does not support the video tag.