AGCOC.COM <br /> PIPE TRENCH DETAIL SCALE: NTS STANDARD PIPE BOLLARD DETAIL SCALE: 1" = 1'-0" <br /> U J <br /> 6" WIDE DETECTABLE UNDERGROUND 4"0 U-SHAPED BOLLARD Z <br /> MARKING TAPE BURIED 6"-12" BELOW FILLED WITH CONCRETE <br /> FINISHED GRADE: EMPIRE #31-143 (EXTENDED DEPTH) <br /> CONCRETE PAVING itZ <br /> PAINT TOP 1/3, YELLOW W <br /> U <br /> ° ° ° ° e < < d ° ° 'Ad G <br /> a <br /> Z \ <br /> i \ °° ° PEA GRAVEL ° ° jj DISPENSERS ON 6" <br /> o° \� BACKFILL / �' \: 3'-6" <br /> o° ° PAINT BOTTOM 2/3, `� ISLAND Z <br /> ° \� <br /> 3" INSIDE 4" °p - PEARL (' Cl) <br /> DOUBLE WALL �\ \� \ \ 4 `� DRIVE SLAB ,^ <br /> VI O <br /> s" s" VAPOR RETURN <br /> 6" 12" 10" 6" 2" INSIDE 3" .4 <br /> °° ° W <br /> ° ° ° a da e d e a ° $ U M <br /> DOUBLE WALL / / / /� <br /> 38" \�\//\//\//\//\/ ° /\//\/\/\/\/\/ fA <br /> \ \ \ rn cyPRODUCT PIPING �\ \ j \ \ < d// coo <br /> VAPOR RECOVERY IN COMBINED VAPOR RECOVERY \\/\\/ < \\/\\/\\/\\/\\/\\/ <br /> SEPARATE TRENCH OPTION AND PRODUCT PIPING TRENCH \\j/\\j/ \\j/\\j/\\j/\\j/\�j\\j ° j� /�� M o <br /> NATIVE SOIL \\//\\/ d /\\//\\//\\//\\//\\//\\ /\\\\\\\ N z ii <br /> \// \ \//\//\//\//\/ \/ //\//\i <br /> j\/j\/j\ ° <br /> NOTE: 72500 <br /> \/NOTE: IN COMBINED TRENCH, MIN. 12' <br /> � \FOR ILLUSTRATION PURPOSES, A BLENDING BETWEEN STAGE II & PRODUCT 1'-3"0 MIN. <br /> GASOLINE OPTION IS SHOWN. FOR A COMBINED PIPING (C.L.) <br /> DIESEL OPTION, ADDITIONAL PIPING IS REQUIRED. PSI CONCRETE FOUNDATIONS SHOWN ARE <br /> MINIMUM REQUIREMENTS; LOCAL BUILDING CODES <br /> OR FROST LINE MAY REQUIRE GREATER DEPTH <br /> 2010 CALIFORNIA FIRE CODE SECTION 2206.7.3 MOUNTING OF DISPENSERS: <br /> DISPENSER SUMP CROSSOVER PIPING DETAIL FOR FRP SCALE: NTS DISPENSING DEVICES EXCEPT THOSE INSTALLED ON TOP OF A PROTECTED ABOVE GROUND TANK THAT <br /> QUALIFIES AS VEHICLE IMPACT RESISTANT, SHALL BE PROTECTED AGAINST PHYSICAL DAMAGE FROM <br /> VEHICLES BY MOUNTING ON A CONCRETE ISLANDS 6 INCHES OR MORE IN HEIGHT, OR SHALL BE <br /> 3" INSIDE 4" VAPOR OTHERWISE BE SUITABLY PROTECTED IN ACCORDANCE WITH SECTION 312.............. <br /> RETURN LEG <br /> TO OTHER CALIFORNIA FIRE CODE SECTION 312.2 POSTS: <br /> CROSSOVER DROPS FROM DISPENSERS GUARD POSTS SHALL COMPLY WITH ALL OF THE FOLLOWING REQUIREMENTS: <br /> EACH DISPENSER 1. CONSTRUCTED OF STEEL NOT LESS THAN 4 INCHES IN DIAMETER AND CONCRETE FILLED z <br /> 2. SPACED NOT MORE THAN 4 FEET BETWEEN POSTS ON CENTER o <br /> 2" INSIDE 3" PRODUCT 3. SET NOT LESS THAN 3 FEET DEEP IN CONCRETE FOOTING OF NOT LESS THAN A 15 INCH DIAMETER. N <br /> PIPING 4. SET WITH THE TOP OF POSTS NOT LESS THAN 3 FEET ABOVE GROUND. <br /> 5. LOCATED NOT LESS THAN 3 FEET FROM THE PROTECTED OBJECT. <br /> CROSSOVERS DROPS AT <br /> MAIN HEADERS (TYP.) �0 <br /> TO TANKS �`0" <br /> UJ <br /> J_ <br /> Z) <br /> m <br /> THE DESIGN MUST BE IN ACCORDANCE WITH CALIFORNIA FIRE CODE, 2010 EDITION #1 SECTION 312 FOR Q <br /> DISPENSERS ON THE REQUIRED 6 INCH ISLAND AND #2 PER CFC SECTION 2203.1.1 FOR DISPENSERS AT <br /> GRADE. REF CFC SECTION 105.4.1. <br /> co <br /> 3" INSIDE 4" VAPOR TO OTHER <br /> DISPENSERS C) <br /> RETURN MANIFOLD TO o z <br /> TANKS <br /> ALTERNATE FIRE EXTINGUISHER FOR DISPENSER AREA INSTALLATION DETAILS SCALE: 1 " = 1'-0" Z <br /> CABINET: KID-FXC-24 <br /> WITH BREAKABLE GLASS, <br /> 24"x10"x6" OR EQUAL 4"x4"xY4" TUBE STEEL <br /> COLUMN <br /> FIRE EXTINGUISHER: <br /> KID-10-460 10# <br /> 4:A-60-BC OR EQUAL <br /> THE CABINET HEIGHT WILL BE <br /> MOUNT FIRE EXTINGUISHER SUCH THAT THE FIRE <br /> CABINET TO TUBE STEEL Co EXTINGUISHER WILL BE NO 3'-8" (TYP.) 3'-0" <br /> COLUMN I HIGHER THAN FIVE FEET TO THE <br /> TOP OF THE EXTINGUISHER FROM <br /> Y4" ANGLE WELD AROUND FINISH GRADE. REF CFC <br /> -�0- <br /> PERIMETER OF TUBE STEEL SECTION 906. <br /> TYPICAL DISPENSER <br /> 8"x8"xY4" STEEL BASE (ACTUAL FOOTPRINT <br /> %"Ox12"L HILTI EPDXY SET PLATE MAY VARY) <br /> THREADED FASTENERS Co <br /> I <br /> GRADE M J <br /> � Z <br /> a O g <br /> d d 4 4 W J <br /> NOTE: [� d d Z O <br /> INSTALL FIRE EXTINGUISHER w NOTE: WHEN DISPENSERS ARE W <br /> AS SHOWN IN DETAILS, DO INSTALLED ON ISLANDS USE <br /> NOT MOUNT TO DISPENSER. STANDARD LENGTH 4"0 U-SHAPED U BOLLARD <br /> CONCRETE FORECOURT DISPENSERS ON ISLAND <br /> vJ <br /> CANOPY COLUMN SPACING TYPICAL FIRE EXTINGUISHER LOCATIONS AT DISPENSER AREA FOR DOMINO CANOPY (WEST OF ROCKIES) <br /> � o � <br /> Z <br /> � zv w <br /> LLJ Lei Z <br /> 0-- o <br /> c� <br /> INSTALL CABINET z ON CANOPY Q <br /> COLUMN (TYP.) � Z W <br /> Do <br /> INSTALL CABINET <br /> ON CANOPY consultant job# <br /> COLUMN (TYP.) <br /> master release date <br /> project master <br /> exe date drawn by <br /> Facility/Project <br /> NOTE: <br /> ACTUAL NUMBER OF FIRE <br /> EXTINGUISHERS TO MEET <br /> TYPICAL DOMINO CANOPY W/ H - FRAME DISPENSERS LOCAL REQUIREMENTS sheet name <br /> SCALE: 1" = 10'-0" G O.5 <br />