Laserfiche WebLink
eThread <br /> (ProductD. <br /> Applications <br /> • Service Station • Central Fuel Oil Systems • Diesel Exhaust Fluid <br /> • Vent/Vapor Recovery • Marinas Terminals • UL/ULC Systems that require MV, <br /> • Bulk Plant Terminals • Ethanol Fuel Blends HB, CT,A&M Fuels <br /> • Fueling Terminals • Biodiesel Fuel <br /> Materials and Construction Fittings Joining System <br /> All pipe is manufactured by filament Fittings are manufactured with the same <br /> winding process using amine-cured epoxy chemical and temperature capabilities as the • T.A.B'" Theprimaryjoiningmethodfor <br /> thermosetting resin to impregnate strands of pipe. Depending on the configurations and pipejointspromotingfast,positive make- <br /> continuous glass filamentswitharesin-rich size,the fittings construction method will up and prevents"backout"d uri ng cu ri ng. <br /> interiorsurface. The operating pressure be compression molded,contact molded, . Bell&Spigot-Theprimaryjoining <br /> ofthe pipe is up to 250 psig(17.2 bar)with fabricated orfilamentwound and are method forfittingjoints. <br /> continuous operating temperature to150•F described inFH1250. <br /> (660C). Thesejoints assistthe installerand assures <br /> Red Thread llAis Listed with Underwriters Testing a fast trouble-free installation. Adhesive for <br /> La boratories Standard 971-2004 for Installed pipe systems should be tested prior this system is Series 8000. T.A.B.spigots can <br /> n on-metallic underground piping for motor to use to assure soundness ofalljointsand be bonded into tapered bells and tapered <br /> vehicle(MV),high blend (HB),concentrated connections, Locate pressure gauge in close spigots can be Bonded into T.A.B. bells using <br /> (CT)and aviation and marine(A&M)fuels. proximity to the pressurizing equipment, standard bonding procedures fortapered <br /> The pipe and fittings are also Listed with not directly on the pipingsystem.A pressure joints. <br /> Underwriters Laboratories of Canada with gauge with thetest pressure at mid-scale is <br /> recommended ASTM D2996 Designation Code- <br /> both Listings under File M H9162. . RTRP-11AW13110 <br /> Nominal Dimensional Data <br /> Pressure/ <br /> inside Outside Temperature Mill Test Minimum <br /> Pipe Size Diameter Diameter Wall Thickness Weight Max. Rating at Pressure Bending Radius <br /> 150°F (660C) <br /> in mm in mm in mm in mm lbs/ft kg/m psig MPa psig MPa ft m <br /> 2 50 2.238 57 2.372 60 0.067 1.70 0.42 0.63 250 1.72 375 2.59 102 31.0 <br /> 3 80 3.363 85 3.559 90 0.098 2.49 0,92 1.37 175 1.21 300 2.07 153 46.5 <br /> 4 100 14.364 111 14.554 116 0.095 2.41 1.15 1.71 125 0.86 1265 1.83 195 s09.56 150 6.408 163 6.686 170 0.139 3.53 2.47 3.68 20 0.14 265 1.83 287 <br /> View of Joint Illustrations <br /> RECEIVED <br /> " - MAR 2 7 1 <br /> ENVIRONMENTAL. <br /> HEALTH DEPARTMENT <br /> T.A.B. Bell&Spigot <br /> Fiber Glass Systems I KOY P nSolutions fgspipe@nov.com nov.com/fgs <br />