My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2023
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
18095
>
2300 - Underground Storage Tank Program
>
PR0548699
>
INSTALL_2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/3/2026 9:08:02 AM
Creation date
10/3/2023 5:01:54 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2023
RECORD_ID
PR0548699
PE
2351 - UST FACILITY - 2481 COMPLIANT
FACILITY_ID
FA0027873
FACILITY_NAME
ARCO AMPM-MOUNTAIN HOUSE
STREET_NUMBER
18095
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
MOUNTAIN HOUSE
Zip
95391
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
18095 W GRANT LINE RD MOUNTAIN HOUSE 95391
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
184
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
a:=company <br /> MA <br /> OWA . .r--- OPW 400 and 500 <br /> Series Multi-Port Spill <br /> Containment Manholes <br /> OPW Multi-Port Spill Containment <br /> Manholes provide spill containment <br /> for underground storage tank(UST) <br /> FSA400 61JSK _ _ fill pipes and vapor recovery risers in a <br /> ' p <br /> completely integrated single manhole <br /> ordering specifications <br /> See page 80 for - package. Multi-ports are installed over <br /> � '� � p g <br /> on the FSA 400&61JSK _ the top of tank sumps to preserve future <br /> access to the tank top and to facilitate <br /> containment of tank bung fittings.OPW <br /> Model Descriptions Multi-PortThread-On Spill containers offers a vast array of standard multi-port <br /> ♦ OPW 411 Series—features a flush- are available in Composite or Cast Iron configurations and options,in addition <br /> mounted manhole lid and raised dual bases with 5 gallon buckets.Drain to an almost unlimited ability to provide <br /> dam and groove spill container rings, Valve Spill Bucket&Plug Spill Bucket custom solutions for virtually any spill <br /> with P2105 Buckets using OPW 1-2105 standard on Dual Ports,Drain Valve containment application. <br /> Style Slip-On 5-gallon containers.Base Spill Bucket standard on Single Port <br /> is standard 1" offset from center and ♦ Required for EVR APPLICATIONS <br /> can be used for 12",14",16" or wider —the FSA-400 Threaded Riser Face ♦ Spill Container Cover Options— <br /> riser spacing.Optional 1 P-2105 Hand Seal Adaptor is installed on the fill standard spill container options include <br /> Pump available pipe below the spill container to the patented OPW dam and groove <br /> ♦ OPW 500 Series(511 /521) EVR provide a true sealing for the drop raintight(RT)design and the <br /> Multi-Port—features a flush- tube flange on the 71 SO overfill watertight Sealable Cover(SC) <br /> mounted manhole lid and raised dual prevention valve.The 61 SO and/or "plumber's plug"design.The raintight <br /> dam and groove spill container ring, 71 SO series valve is installed in the cover features a finger-grip lifting <br /> with 511-EVR Buckets base of the OPW EVR spill container facility and an integral seal.The <br /> w P ts using OPW <br /> ith Style Thread-Onis Spill with the patent pending 61 JSK jack Sealable Cover features a cam- <br /> ContainersAll Fill Ports in these spill screw device.This configuration allows operated mechanism that expands the <br /> containers feature an enhanced liquid in the spill container to be seal against the vertical wall of the <br /> 1 containers <br /> feature <br /> vapor tight drain valve. drained directly into the drop tube, mounting ring.Both of these water- <br /> The Vapor Return Spill Container thereby isolating the drain valve from shedding covers are protected by <br /> features a permanent plug in the drain the tank ullage,eliminating a notorious raised mounting rings. <br /> port as per EVR requirements.EVR leak point in previous systems ♦ Fastener Options—two types of <br /> fasteners are available to secure the <br /> Features ♦ FiIINapor Ports—configurations are manhole lid and monitoring port to <br /> available to accommodate a single fill mounting rings.Standard are <br /> ♦ Contractor-Friendly Installation riser,dual ports for both a fill and 5/16"-18 hex head bolts.Optional <br /> —studded mounting ring simply bolts vapor riser,and triple and quad ports are OPW Roto-Lock Fasteners. <br /> together inside the spill containment for multiple fill and vapor risers.Ports The OPW Roto-Lock system enables a <br /> bucket.No need to align bolt holes in can be supplied with or without secure,watertight connection without <br /> the manhole cover containment buckets the need to locate threaded bolt holes <br /> ♦ Raintight Service—nitrile gaskets ♦ Port Configurations—standard port on the mounting ring. <br /> on the manhole ands ill bucket ♦ Powder Coated Rings& Covers— <br /> P locations match the popular riser <br /> mounting rings help prevent spacings(16" or 24 )and bung available upon request. <br /> contamination of the sump area configurations on underground storage ♦ Replacement Covers—see Part <br /> from surface water intrusion tanks.Custom port locations are easily Number Configurations at <br /> ♦ Highway 20 Load Rating—the accommodated.For riser spacings less www.opwgiobal.com. <br /> rugged diamond plate steel manhole than 16",old style buckets must <br /> covers,as well as the ductile iron(RT) be used Listings and Certifications <br /> or aluminum(SC)spill container covers ♦ CARB Certified—500 Series CARB <br /> meet H2O Load Rating requirements EVR Approved Executive Order#VR-102 Look for this label for <br /> ♦ Spill Container and Manhole ♦ Manhole Cover Sizes—standard U C authentic OPW EVR <br /> Positive I.D.System—special bolt-down manhole cover diameters ;® Approved products. <br /> recesses cast into spill container covers of 30" (76 cm),37" (94 cm),42" =`""_ <br /> allow product I.D.tags to be attached (107 cm)and 48" (122 cm)allow CARB EVR Executive Order#VR-102 <br /> to the lids.Matching bucket tags can ample access to the sump area.Heavy- NYCFD Certified(6571 Series)#5053 <br /> be affixed to the inside of the spill duty reinforced lid options are also Florida EQ-145 <br /> container to prevent covers from available upon request <br /> getting switched <br /> 92 9393 Princeton-Glendale Road o Hamilton,Ohio USA 45011 4 Phone:(800)422-2525 <s Fax:(800)421-3297 <br />