Laserfiche WebLink
Secondary Containment <br /> Vacuum Sensing System <br /> Maximize protection with a vacuum <br /> monitored secondary containment MYy ► <br /> system . <br /> A Secondary Containment Vacuum Features and Benefits Facilitates periodic operability testing <br /> Sensing System for use with Veeder- Satisfy Requirements Leverage Existing Veeder-Root Systems <br /> Root's ATG Systems. The Secondary rrxnfie� to meet Califomia's requiremesnt for Uses STP as the vacuum source and worts with <br /> secondary space monitoring for tanks and lines Red admt and FE SIPs <br /> Containment Vacuum Sensing (S CVS) as rqui ed byAB 2481 , Installs in the S'IP Sump and conIleCLS to the <br /> System is designed to detect leaks in double- Satisfies the requirements for Class I Leak co ng <br /> walled tanks and piping systems while Detection as definedby the European Able to sle a miming conduitw�Safe th <br /> helping to contain a release of product while Standard IN 13160-2 Abletoshare c°ndtntwuh°� <br /> P g P Veeder--Root intrinsically safe(IS)probes and <br /> 3ni Parry <br /> under vacuum. The system consists of: National Mbrk Group and LG113listed sensors including stung or line leak sensors <br /> • Interfaces to the Smart Sensor Interface with <br /> • Vacuum Sensors, connected to tank, Reduce Exposure to Rich Embedded Pressure Module <br /> sump or piping interstices Alarms when vacuum cannot be maintained • Provides for positive shut down of pressurized <br /> or when replenish rate exceeds 85 liters ers per hour lines when.required <br /> • A Submersible Turbine Pump (STP), The system alarm when liquid s deteaed m Simple inura➢adon,m need to mess with brine <br /> to provide a source of vacuum the secondary space <br /> • A Smart Sensor Interface with Embedded <br /> Pressure Module in a TLS-350 Operating Temperature Rating: Console Capability <br /> Monitoring System -25 degrees C to+70 degrees C The Vacuum Sensor is compatible with <br /> the following consoles: <br /> Cable Length: Console <br /> The Vacuum Sensor is interfaced to Veeder- 8 feet TLS-050R/EMC w/BIR• <br /> Root's TLS-350 Monitoring System via TLS-350 Plus/EMC Enhanced* <br /> intrinsically safe wiring to provide system Sensor Dimensions: TLS-350/EMC' <br /> status, replenish rate, alarm, and diagnostic 5" high x 5"wide 2" deep 'Upgrade Note:The Vacuum Sensor System requires <br /> the console to have version 24C software or greater) <br /> information. along with an ECPU2 or ECPU w/NVMEM 1 board. <br /> Standard Models <br /> Vacuum Sensor Kits are available in a variety Veede'rrvRooif P/N-- Description <br /> of models: 33ob26-4Fi7 4 Vacuum Sensor Krt•for steel tank <br /> 330020-468,469,470,471 4 Vacuum Sensor Kt`for fiberglass tanks(4%6',8',10') <br /> 330020-486 4 Vacuum Sensor Kt•for no tank <br /> • For monitoring double-walled piping 330020-472 3 Vacuum Sensor Kt•for steel tank <br /> 330020-473,474,-475,476 3 Vacuum Sensor 1w for fiberglass tanks(4%6',8',101) <br /> and sump interstices 330020-485 3 Vacuum Sensor Kr for no tank <br /> • For monitoring double-walled steel tank: 330020479 2 Vacuum Sensor tar for steel tank <br /> interstices (see back page) 330020-481,482,483,-484 2 Vacuum Sensor IGr for fiberglass tanks(4%6',8',10'j <br /> 330020-480 2 Vacuum Sensor Kr for no tank <br /> • For double-walled fiberglass tanks 330020-495 1 Vacuum Sensor 1,W for no tank <br /> 857280-100 Vacuum Sensor for piping&sumps <br /> These kits differ in the number of vacuum 857280-200 Vacuum Sensor for steel tanks <br /> 857280-301,-302,-303,-304 Vacuum Sensor for fiberglass tanks(4',6,8,10) <br /> sensors and the configuration of associated 330020448 Mounting Kit <br /> liquid sensors. An in]ine kit mounted liquid 332217-001 Relief Valve Assembly <br /> sensor is used for Vacuum Sensors 332250-001 Smart Sensor w/Embeddd Pressure Sensor Module(7 Channel)" <br /> monitoring piping and sumps. An external Accessories Part Deser pt* _ guantiiy/l.ength Part Number <br /> 1/4" NPT Barbed Fittings 3 330020-487 <br /> liquid sensor (to be installed in the secondary 1/4" NPT Barbed RdIngs 15 330020488 <br /> space at the bottom of the tank) is provided 1/4"NPT Barbed Fittings 25 330020-489 <br /> 576008-657 <br /> with one of the Vacuum Sensors in the steel Barbed Tee 1 332310-001 <br /> g��VE Vacuum Hose 50' s25'o, 332310-001 <br /> and fiber for the tank. vacuum Hose 50' So' 332310-002 <br /> Vacuum Hose 100' 100, 332310-003 <br /> 3-Way Ball Valve 1 576008-649 <br /> Schrader <br /> alve Barbed Fitting 3 330020-496 <br /> MAY 2 4 `H 3 Schrader VValve Barbed Frtting 5 330020 497 <br /> Kts Include mounting bracket,6'of vacuum hose,relief vahie assembly(d required)and ft appropriate number of Squid sensors, <br /> ENVIRONMENTAL 3-my ball valves, barbed frtlings and hose clamps so that each vacuum sensor can monitor a single tank,sump or piping interstices. <br /> HEALTH DEPARTMENT The Modules(p System requires ca°be used fone 7 r\bcuum Sensors e(ghf and above Embedded Pressure Module,a channel Smart <br /> For more information call: 1-888-561-7942 <br /> VEEDER-ROOT <br />