My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2023 AS BUILT PLAN
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
J
>
JACKSON
>
2226
>
2300 - Underground Storage Tank Program
>
PR0548528
>
INSTALL_2023 AS BUILT PLAN
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/4/2023 12:58:07 PM
Creation date
10/4/2023 12:54:57 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2023 AS BUILT PLAN
RECORD_ID
PR0548528
PE
2351
FACILITY_ID
FA0000370
FACILITY_NAME
ORLANDOS ESCALON
STREET_NUMBER
2226
STREET_NAME
JACKSON
STREET_TYPE
AVE
City
ESCALON
Zip
95320
APN
22727016
CURRENT_STATUS
01
SITE_LOCATION
2226 JACKSON AVE
P_LOCATION
06
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(E) BIG BOY MARKET <br />FS1.1 <br />TANKS AND LINES <br />SITE PLAN <br />20 TANKS AND LINES SITE PLAN <br />1" = 10'-0"SCALE: <br />THIS SITE PLAN IS FOR REFERENCE ONLY. SEE SHEET CIVIL FOR GENERAL <br />INFORMATION ON THE ENTIRE SITE. SEE FS1.2 FOR ENLARGED SITE PLAN <br />FOR FUELING <br />PIPING GENERAL NOTES <br />FUEL KEY NOTES <br />FUEL LINE LEGEND <br />5 <br />2 <br />3 <br />1 <br />GENERAL TANK & LINE NOTES <br />THESE PLANS ARE DIAGRAMMATIC IN NATURE AND ARE NOT INTENDED TO BE AN EXACT <br />REPRESENTATION OF THE FINAL PRODUCT. GENERAL CONTRACTOR TO RELOCATE, <br />MODIFY, OR MAKE ADJUSTMENTS TO PROVIDE A COMPLETE AND WORKING SYSTEM, <br />CONSISTENT WITH THE INTENT OF THE DESIGN. CONTRACTOR SHALL COMPLY WITH ALL <br />STATE, FEDERAL AND LOCAL REQUIREMENTS. <br />INSTALL NEW DOUBLE WALL PIPING FROM 2-UST TANKS - 1-20,000 GAL 87 UNLEADED; <br />20,000 GAL: SPLIT TANK - 1-10,000 GAL 91 UNLEADED; 1-10,000 GAL DIESEL <br />ALL AUTO FUEL PRODUCT LINES (2") AND SECONDARY CONTAINMENT (3" PIPING SHALL BE <br />100% METHANOL COMPATIBLE), U.N.O. ON PLAN. SMITH RED THREAD IIA IS SPECIFIED. <br />ALL GLUES SHALL BE PERMEATED 51-D. ALL VENTS UP TO GRADE SHALL BE 100% <br />METHANOL COMPATIBLE. ALL NEW PIPING TO BE INSTALLED PER MANUFACTURER'S <br />SPECIFICATIONS. SLOPE PIPING 1/4" PER FOOT BACK TO TANKS. <br />INSTALL 4"/3" DOUBLE WALLED VAPOR RECOVERY LINES FROM DISPENSERS. SLOPE 1/4" <br />PER FOOT 87 GAS TANK. <br />4 <br />6 CFC 2305.3 REQUIRES SPILLS TO BE PREVENTED FROM FLOWING INTO BUILDINGS. THE <br />FINISH FLOOR OF THE BUILDING IS 1' MIN HIGHER THAN ALL FUELING OPERATION <br />LOCATIONS. <br />INSTALL 3"/2"" DOUBLE WALLED VENT LINES FROM TANKS TO VENT STACK. SLOPE 1/4" <br />PER FOOT BACK TO TANK. <br />DIESEL <br />VAPOR RECOVERY <br />VENT LINE <br />87 UNLEADED <br />91 UNLEADED <br />SEE SHEET FS2.0 FOR EQUIPMENT LIST <br />NOTE: <br />1.ALL PIPING SHALL BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE <br />MANUFACTURER'S INSTALLATION SPECIFICATIONS AND INSTRUCTIONS SEE NOTES <br />BELOW <br />2.FIBERGLASS PIPING SHALL BE LIMITED TO THE FOLLOWING: <br />SMITH FIBERGLASS RED THREAD IIA FOR PRODUCT, VENT AND VAPOR LINES, USING <br />ONLY DS8000 SERIES ADHESIVES TO JOIN PRIMARY PRODUCT AND SECONDARY <br />CONTAINMENT PIPE AND ALCOHOLS AND FITTINGS FOR ALCOHOL-GASOLINE <br />MIXTURES. WHEN JOINING SECONDARY CONTAINMENT FITTINGS, A SPECIAL FILLER <br />FROM SMITH FIBERGLASS PRODUCTS MUST BE ADDED TO THE DS8000 SERIES <br />ADHESIVES. <br />A)SMITH FIBERGLASS SYSTEMS: <br />3.ALL PIPING SYSTEMS SHALL BE TESTED PER CODE. <br />MIN. AMOUNT OF <br />PEA GRAVEL ABOVE <br />THE TOP OF THE PIPE <br />MINIMUM <br />BURIAL <br />DEPTH <br />SURFACE <br />CONDITION <br />PIPE <br />SIZE <br />PIPE <br />MANUFACTURER <br />SMITH FIBERGLASS <br />RED THREAD IIA <br />12" <br />8" <br />5" <br />14" <br />9" <br />7" <br />14" <br />10" <br />7" <br />17" <br />12" <br />9" <br />20" <br />13" <br />11" <br />20" <br />14" <br />11" <br />2" <br />3" <br />4" <br />4.PIPING TO BE INSTALLED WITH THE MINIMUM DEPTHS LISTED BELOW. <br />ALL CROSSOVERS OF PIPING SHALL HAVE 6" MINIMUM BETWEEN PIPES. <br />UNPAVED <br />PAVED, ASPHALT <br />(4" MINIMUM) <br />PAVED, CONCRETE <br />(4" MINIMUM) <br />UNPAVED <br />PAVED, ASPHALT <br />(4" MINIMUM) <br />PAVED, CONCRETE <br />(4" MINIMUM) <br />UNPAVED <br />PAVED, ASPHALT <br />(4" MINIMUM) <br />PAVED, CONCRETE <br />(4" MINIMUM) <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />9 <br />10 <br />11 <br />12 <br />13 <br />14 <br />15 <br />16 <br />MOUNT EMERGENCY FUEL SHUT-OFF SWITCH, +48" ON CANOPY COLUMN. <br />PROVIDE SIGN PER DETAIL , 9/FS4.0 <br />TLS 450 PLUS <br />MSB <br />FUEL ELECTRICAL PANELS <br />VENT LINES <br />FUEL LINES <br />CASHIER FUEL CONTROLS <br />LOCATION OF FIRE EXTINGUISHER IN SURFACE MOUNTED CABINET. MUST BE <br />WITHIN 75' OF ALL DISPENSERS AND FILLS. FIRE EXTINGUISHER SHALL BE <br />2-A:20-B:C RATED. CFC 2305.5 <br />FUEL DISPENSER WARNING SIGN, TO BE VISIBLE WITHIN 10' OF EACH <br />DISPENSER. THESE STICKERS ARE LOCATED ON EACH DISPENSER. SEE DETAIL <br />11,17/FS4.0 <br />20K UST FOR 87 REGULAR UNLEADED GAS TANK <br />10K UST SPLIT FOR 91 PREMIUM UNLEADED GAS TANK <br />10K UST SPLIT FOR DIESEL GAS TANK <br />TANK OVER FILL ALARM AND RESET BUTTON <br />VENT SUMP AND RACK WITH CANISTER <br />AUTO DRIVE SLAB, SEE DETAIL 2/FS4.0 <br />TSL 450 REMOTE ALARM <br />ATTENDANT INTERCOM SYSTEM CONSOLE TO ALL DISPENSERS. <br />CROSS-OVER DW PIPE <br />17R100'-0"13 <br />14 <br />10 <br />11 <br />12 <br />6 <br />5 <br />8 <br />15 <br />3 <br />27 <br />17 <br />16 <br />9 <br />1 <br />SHEET NUMBER: <br />SHEET CONTENTS: <br />PROJECT NUMBER:PROJECT DATE: <br />CONSULTANTS: <br />Sacramento, CA 95827 <br />PH:(916) 455-6500 FAX:(916) 455-8100 <br />3090 Fite Circle, #104 <br />REVISIONS: <br />21-004 3-4-2021 <br />K12 Architects, Inc <br />DEVELOPER: <br />CONTRACTOR: <br />PROJECT: <br />BIG BOY <br />MARKET <br />CHEVRON <br />FUEL <br />PROFESSIONAL SEALS: <br />2226 Jackson Avenue <br />Escalon, California 95320 <br />FUELING CANOPY <br />PLAN REVIEW CHANGES 12/21/2022 <br />PLAN REVIEW CHANGES 01/09/2023 <br />FUEL CHANGES 2/03/2023 <br />2/3/2023 <br />TANK CHANGE 2/20/2023 <br />TANK CHANGE 3-14-23 <br />EHD-Hazmat Comments 4-7-23 <br />AS BUILT 8-15-23 <br />6 <br />4 <br />UNDERGROUND TANKS <br />AUTO ISLAND <br />ELIZABETH AVEJACKSON AVENUE <br />9 <br />10K D <br />20K U <br />10K SFILL FILL <br />FILL <br />18 <br />18 <br />18 <br />18 <br />2 <br />2 <br />3 <br />3 <br />4 <br />7 <br />7
The URL can be used to link to this page
Your browser does not support the video tag.