My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HARDING
>
2900
>
1600 - Food Program
>
PR0548532
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/19/2023 3:42:25 PM
Creation date
10/19/2023 3:41:28 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0548532
PE
1635
FACILITY_ID
FA0027738
FACILITY_NAME
LOPEZ MEXICAN FOOD #4VE2175
STREET_NUMBER
2900
Direction
E
STREET_NAME
HARDING
STREET_TYPE
WAY
City
STOCKTON
Zip
95205
APN
14310020
CURRENT_STATUS
01
SITE_LOCATION
2900 E HARDING WAY
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\ymoreno
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN <br /> <br />Environmental Health Department <br />COUNTY <br />than twenty-four (24) inches. Splash guard shall be at least six (6) inches in height from <br />back edge to front edge [CRFC §113953]. <br />Mobile Food Facilities where nonprepackaged food is cooked, blended, or otherwise <br />prepared shall provide a warewashing sink with at least three compartments with two <br />integral metal drainboards. The dimensions of each compartment of the warewashing <br />sink shall be at least 12 inches wide, 12 inches long, and 10 inches deep, or large enough <br />to accommodate the cleaning of the largest utensil. Each drainboard shall be at least the <br />size of one of the sink compartments. The drainboards shall be installed with at least one- <br />eighth inch per foot slope toward the sink compartment, and fabricated with a minimum <br />of one-half inch lip or rim to prevent the draining liquid from spilling onto the floor. (CRFC <br />Section 114313) <br />Light bulbs and tubes shall be covered and completely enclosed in plastic safety shields <br />or the equivalent. (CRFC Section 114323) <br />Potable water tanks shall be sufficient in volume to fulfill the required 5 gallon minimum <br />for hand washing. Facilities with limited food preparation must provide at least 15 <br />additional gallons of water for warewashing. For any preparation beyond limited food <br />preparation at least 25 additional gallons of water for warewashing and food preparation <br />must be provided. (CRFC Section 114217) <br />Tanks shall be adequately vented for flow. Water tank vents shall terminate in a <br />downward direction and shall be covered with 16-mesh per square inch screen or <br />equivalent when the vent is in a protected area or a protective filter when the vent is in <br />an area not protected from windblown dirt and debris. (CRFC Section 114213) <br />Mechanical exhaust ventilation equipment shall be provided over all cooking equipment, <br />including the electric fryer, as required to effectively remove cooking odors, smoke, <br />steam, grease, heat, and vapors. All mechanical exhaust ventilation equipment shall be <br />installed and maintained in accordance with the California Mechanical Code. Makeup air <br />shall be provided the rate of that exhausted [CRFC §114149.1] <br />12.All manufactured and custom-made food service equipment must be certified for <br />`1 sanitation by an American National Standards Institute (ANSI) accredited <br />certification program. All proposed equipment is subject to EHD approval [CRFC <br />§114130]. <br />13.Wastewater tanks shall have a minimum capacity that is 50 percent greater than the <br />potable water tanks. In no case shall the wastewater capacity be less than 7.5 gallons. <br />Where potable water for the preparation of a food or beverage is supplied, an additional <br />wastewater tank capacity equal to at least 15 percent of the water supply shall be <br />provided. (CRFC Section 114240) <br />2 of 3
The URL can be used to link to this page
Your browser does not support the video tag.