Laserfiche WebLink
Program Element: 3601 - NEW POOL/SPA PLAN CHECK <br />Telephone: (539) 593-5632 Requestor: JOANNE, FREEDOM POOLS <br />Inspection Type: 523 - Plan Check/Report Review <br />Address: 3651 ARCH RD , STOCKTON 95215 <br />Date: 02/13/2023Name of Facility: HAMPTON INN <br />Swimming Pool Service Request Inspection Report <br />12:00 pm <br /> 1:30 pm <br />Time Out: <br />Time In: <br />Request #: SR0085409 <br />Environmental Health Department <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br />OVERALL INSPECTION NOTES AND COMMENTS <br />NOTES <br />Pool ispection <br />Pool has been gunited <br />Must comply with the follwing: <br />3137B.1 The suction outlets shall be hydraulically balanced and symmetrically plumbed through one or more “T” fittings and <br />shall be separated by a distance of at least 3 feet (915 mm) in any dimension between the suction outlets; and <br />2. All suction outlets shall be equipped with suction fittings that meet the ANSI/APSP-16 2011 performance standard; and <br />3. The velocity of the suction piping installed between the suction outlets shall not exceed 3 feet per second (.91 mps) under <br />normal operation, or 6 feet per second (1.82 mps) if one outlet is blocked. <br />3111B.3 Stairs. Each step of a stair shall have a tread in accordance with Figure 31B-7. Risers shall conform to Figure 31B-7. <br />At least one hand rail shall be provided extending from the deck to not less than a point above the top of the lowest step <br />installed in accordance with Figure 31B-7. <br />Tread: top step must be 21 inches to 24 inches, the rest of the steps must be 12 inches to 16 inches and must be unformed. <br />Risers: steps must be 6 inches to 12 inches and must be uniformed. <br /> Call for a preplaster inpection. <br />The person in charge is responsible for ensuring that the above mentioned facility is in compliance with all applicable sections of the California Health and <br />Safety Code. If a reinspection is required, fees will be assessed at the current hourly rate. <br />Received by: Name and Title: <br />EH Specialist:Phone:(209) 616-3020 <br />, <br />VIDAL PEDRAZA <br />Page 1 of 1EHD 36-01 Rev. 07/05/2022 Swimming Pool Service Request Inspection Report <br /> SR0085409 SC523 02/13/2023