Laserfiche WebLink
e VEEDER ROOT <br /> �M <br /> ELectronic Pressurized Line Leak Detection <br /> Why Electronic PLLD for Detecting Line Leaks? <br /> The Veeder-Root Electronic Pressurized Line Leak Detection (PLLD) system is designed to meet your everyday compliance needs. Our <br /> patented technology performs precision line leak testing at full pump pressure for 0.1 and 0.2 gallons per hour (gph) and a pressure <br /> decay test to meet the U.S. EPA 3.0 gph test requirements.The Veeder-Root Electronic PLLD system works in a variety of pressurized line <br /> applications,and offers flexible testing and digital reporting options,helping to detect catastrophic leaks.When paired with a TLS-450PLUS <br /> Automatic Tank Gauge(ATG),customers can monitor up to 1178 gallons of fuel line volume. <br /> 7 �LEAK DETECTED FAIL <br /> If the pressure is out of normal range,the TLS-450PLUS will record a failing result and generate an audible and visual alarm for the store operator. <br /> SYSTEM FEATURES <br /> • Pressure sensor is installed without breaking piping or adding a new sump,and is constructed with stainless steel <br /> to meet the challenges of a highly corrosive environment. <br /> • Test lines at full pressure for quick and accurate results,without restricting fuel flow rate. <br /> • Conducts a 3.0 gph test,which meets EPA and NFPA 30 release detection requirement for pressurized line systems, <br /> once all dispensing is completed to ensure the integrity of the line. <br /> • Standard 3.0 gph and optional 0.1 and 0.2 gph tests can be manually performed to reset alarms. <br /> • Monitors line pressure during dispensing activity to ensure a catastrophic leak is not occurring during a dispense. <br /> If a leak is detected at a pre-set pressure threshold,the system will shutoff power to the Submersible Turbine Pump <br /> (STP)to minimize environmental damage and prevent a public safety issue. <br /> • Built-in calibration verification to notify the site operator when the pressure transducer is not operating properly. <br /> • Auto-Confirm function,when enabled,runs a second line leak test,if an initial test failure occurs,to verify and reduce <br /> false alarms due to mechanical issues that may be occurring in other parts of the fueling system. <br /> • Provides two alarm shutdown options when failure occurs:Standard Dispenser Shutdown(Alarm and Shutdown) <br /> and Optional No Shutdown(Alarm Only). <br /> • Not impacted by thermal contraction of fuel in the line due to changes in temperature. <br /> www.veeder.com <br />