My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2023
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WILSON
>
4343
>
2300 - Underground Storage Tank Program
>
PR0548708
>
INSTALL_2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/30/2025 11:48:33 AM
Creation date
11/21/2023 2:43:29 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2023
RECORD_ID
PR0548708
PE
2351 - UST FACILITY - 2481 COMPLIANT
FACILITY_ID
FA0027878
FACILITY_NAME
IGRA INVESTMENTS INC
STREET_NUMBER
4343
STREET_NAME
WILSON
STREET_TYPE
WAY
City
STOCKTON
Zip
95391
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\lsauers1
Supplemental fields
Site Address
4343 WILSON WAY STOCKTON 95391
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
201
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LG 162-2 - 5 - <br /> 25290.2(d) <br /> 5 -25290.2(d) include, but are not limited to, riser piping and access points on top of <br /> the tank, which provide access to the primary containment of the tank and may <br /> be in contact with vapors of the stored product. <br /> 10. For USTs installed on or after July 1, 2003 and prior to July 1, 2004, is an <br /> annual line tightness test on pressurized piping required? <br /> Yes. As for all USTs installed since January 1, 1984, the requirement for <br /> "underground pressurized piping ... (to) be tightness tested annually" also applies <br /> to USTs installed on or after July 1, 2003 and prior to July 1, 2004. [H&S Code, <br /> §25290.2(g); H&S Code, §25291(f).] The annual line tightness testing requirement <br /> may be met by satisfying the criteria specified in CCR, Title 23, Section 2636(g)(1- <br /> 5). <br /> PART II: USTs INSTALLED ON OR AFTER JULY 1, 2004. <br /> In addition to the requirements discussed below (Questions A-D of Part II), USTs <br /> installed on or after July 1, 2004 are subject to all of the installation and monitoring <br /> requirements presented in the responses to Questions 1-8 of Part I. For USTs installed <br /> on or after July 1, 2004, references to the "July 1, 2003" date in Part I should be <br /> substituted with "July 1, 2004." The H&S Code citations relevant to USTs installed on or <br /> after July 1, 2003 and July 1, 2004 are provided in the table below. Note that Questions <br /> 9 and 10 of Part I do not apply to USTs installed on or after July 1, 2004. <br /> H&S Code Citation for USTs H&S Code Citation <br /> Installed On or After July 1, 2003 and for USTs Installed <br /> Question Prior to July 1, 2004 On or After July 1, 2004 <br /> Number Part I Part II <br /> 1 H&S Code §25290.2(a) H&S Code §25290.1 a <br /> 2 <br /> 3 H&S Code §25290.2(c)(3) H&S Code 25290.1(c)(3) <br /> 4 H&S Code §25290.20) H&S Code §25290.1(k) <br /> 5 H&S Code §25290.20) H&S Code 25290.1 k <br /> 6 H&S Code §25290.2(i) H&S Code §25290.1 <br /> 7 H&S Code 25290.2 H&S Code 25290.1 <br /> 8 H&S Code §25290.2 H&S Code §25290.1 <br /> A. In accordance with H&S Code, Section 25290.1(e), which components of <br /> USTs installed on or after July 1, 2004 must be continuously monitored <br /> using vacuum, pressure, or interstitial liquid level measurement methods? <br /> The interstitial space of the tank and product piping (including fill, vent, and vapor <br /> recovery piping), that are beneath the surface of the ground must be maintained <br /> under constant vacuum or pressure. Statute also requires that a breach in the <br /> primary or secondary containment be detected before the liquid or vapor of the <br /> stored substance is released to the environment. Continuous vacuum, pressure, <br /> or interstitial liquid level measurement methods can be used to satisfy these <br /> California Environmental Protection Agency <br /> Zai Recycled Paper <br />
The URL can be used to link to this page
Your browser does not support the video tag.