My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2023
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WILSON
>
4343
>
2300 - Underground Storage Tank Program
>
PR0548708
>
INSTALL_2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/30/2025 11:48:33 AM
Creation date
11/21/2023 2:43:29 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2023
RECORD_ID
PR0548708
PE
2351 - UST FACILITY - 2481 COMPLIANT
FACILITY_ID
FA0027878
FACILITY_NAME
IGRA INVESTMENTS INC
STREET_NUMBER
4343
STREET_NAME
WILSON
STREET_TYPE
WAY
City
STOCKTON
Zip
95391
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\lsauers1
Supplemental fields
Site Address
4343 WILSON WAY STOCKTON 95391
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
201
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
W PIPING GENERAL NOTES <br /> i \ \ WWWWWWWWWWWWWWWW WWW WWWW WW W W W W W WWW WWWW WWW <br /> \ % W W W W W W W w W W 1. ALL PIPING SHALL BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE <br /> W <br /> W W W W W <br /> j \ \ MANUFACTURER'S INSTALLATION SPECIFICATIONS AND INSTRUCTIONS SEE NOTES ON <br /> NBERGLA65 PIPING SHALL BE LIMITED TO THE FOLLOWING: <br /> I \ \% A) SMITH FIBERGLASS SYSTEMS: <br /> \ \ SMITH FIBERGLASS RED THREAD IW FOR PRODUCT,VENT AND VAPOR LINES,USING <br /> \ 5a ONLY D58000 SERIES ADHESIVES TO JOIN PRIMARY PRODUCT AND SECONDARY <br /> \ \ CONTAINMENT PIPE AND ALCOHOLS AND FITTINGS FOR ALCOHOL-GASOLINE <br /> MIXTURES.WHEN JOINING SECONDARY CONTAINMENT FITTINGS,A SPECIAL MILLER <br /> ! \ % FROM SMITH FI6ERGLA55 PRODUCTS MUST BE ADDED TO THE D56000 SERIES <br /> ! \ \ ADHESIVES. <br /> \ % 3. ALL PIPING SYSTEMS SHALL BE TESTED AS FOLLOWS:SEE <br /> \ \ E/F511 FOR TESTING REQUIREMENTS. <br /> ` 4. PIPING TO BE INSTALLED WITH THE MINIMUM DEPTHS LISTED BELOW. <br /> W W W W W W W W W W <br /> \ ALL CROSSOVERS OF PIPING SHALL HOVE 6'MINIMUM BETWEEN PIPES. <br /> MINIMUMMIN.AMOUNT OF <br /> \ \% PIPE PIPE SURFACE BURIAL PEA GRAVEL ABOVE K12 Architects,Inc <br /> MANUFACTURER SIZE CONDITION DEPTH THE TOP OF THE PIPE 3090 Fite Circle,#104 <br /> SMITH FIBERGLASS 2" UNPAVED 17 12' Sacramento,CA 95827 <br /> W W W RED THREAD IIA PAVED,ASPHALT 12" 6 pH:(916)455-6500 FAX:(916)455-8100 <br /> (4'MINIMUM) <br /> W POND 9D3 sf W °• ... .° °. ... .° \ `W9 r W W W W W % 3 PA(�PNIMUM)TE O 5 mN rxnxs <br /> AVED <br /> 14 <br /> 2 ,\ Lt I 16 - u J PAVED,ASPHALT 13 9" <br /> (4�MINIMUM) <br /> WW'•ryI1IIWW WW WW W W W o PAVED,CONCRETE 1P <br /> 7 <br /> (4'MINIMUM) <br /> WT_ 1 _ 174UNPAVED 20 14 <br /> PAVED.ASPHALT 14 10 <br /> 4'MINIMUM <br /> •^ <br /> Wj W W W W W W ° II PAVED,CONCRETE 1P 7 <br /> W <br /> W W W W <br /> (4'MINIMUM) <br /> WjW W W W W W W W W W W B i o III o x orz <br /> WIW mW W W,i,W W W LI ' II <br /> W W W f II <br /> II <br /> Wj W W WWWW L I� <br /> wW W I <br /> W i W W C•STORE IIS FUEL KEY NOTES <br /> W W W W W W WWW it O MOUNT EMERGENCY FUEL 5HUT-OFF EWI7CH,,48"ON CANOPY COLUMN. — <br /> PROVIDE SIGN PER DETAIL,9/FS4.0 <br /> W W I 3 3 �� <br /> W W I I 2 TLS 45o vLus <br /> .IW 4 <br /> W I 0 - <br /> I � Lrd <br /> W <br /> W � <br /> I 3 MSB 1� �-J J,�f <br /> W I <br /> WjW W I W � <br /> wWW W II W � _ I <br /> 4 FUEL ELECTRICAL PANELS <br /> .r <br /> I <br /> W vt W W W I I OS VENT LINES <br /> ` L <br /> O FUEL LANES <br /> IL_ I I <br /> WyW+W�Ii WW WW WW WW WWW <br /> JL JL ,__ I ❑ <br /> I <br /> O <br /> CASHIER FUEL CONTROLS <br /> L IO _ CF <br /> ERIN SURFACE MOUNTED CABINET.MUST BE <br /> CONVENIENCE STORE <br /> & <br /> 19 N� AND FILLS.FIRE EXTINGSHALL BE FUELING CANOPY <br /> RATED,CFC <br /> 23055 <br /> W W — -- — — --• i <br /> FUEL DISPENSER WARNING SIGN,TO BE VISIBLE HID OF EACH <br /> EACH <br /> W <br /> 74 I ._____' ---�- I I O DISPENSER.THESE STICKERS ARE LOCATED ON EACH DISIS PENSER.SEE DETAIL <br /> 11.17/FS4.o <br /> North Wilson Way <br /> 10 <br /> • W � W <br /> _ <br /> 2or UST FOR 87 REGULAR UNLEADED GAS TANK <br /> WI on California I Q D <br /> !' W W ml I ✓° I I Stockton, <br /> 95205 <br /> 8 a <br /> EF 11 I W W W W - I for UST SPOT TANK FOR 91 PREMIUM UNLEADED GAS TANK <br /> fit12 lor UST SPOT TANK FOR DIESEL GAS TANK <br /> W m m, - m• ✓i I�\ / I 13 TANK OVER RLL ALARM AND RESET BUTTON <br /> 14 VENT SUMP AND ROCK WITH <br /> CANISTE A <br /> —_ _— 15 BTHICK CONCRETE FOR TRUCK DRIVE SLOB,SEE DETAIL 2/F54.0 <br /> 0 G <br /> URPARTAP SINGH�0 <br /> IGRA INVESTMENTS <br /> 6 W I 6 CTLs Azo vLus MOTE ALARM <br /> I I ;■ II g 62 N.SIERRA MADRE ST. <br /> W W II 5 I 17 ATTENDANT INTERCOM SY5EM CONSOLE TO ALL DISPENSERS. MOUNTAIN HOUSE,CA 95391 <br /> W WIW W W j l W I I I 19 18 25K UST FOR DIESEL GAB TANK <br /> I I <br /> W TENANTI ,9 BK UST FOR DEFGASTANK <br /> I I I SPACE I ° <br /> WIW W ~ I W W I 20 17 0 BOLLARDS FOR TRUCK ISLAND,SEE DETAIL 9/FS43 i�OWNER CHANGES 03/01/2022 <br /> 2 <br /> • 2511 D --fI PLAN CHECK 05/12/2022 <br /> WIW W W O i , I W ■ I I L� BUILDING DEPT REVISIONS 08/082022 <br /> wo I W I <br /> V W U'C j j W I Q OWNER CHANGES 10/042018 <br /> I I I NOTE: <br /> = L SEE SHEET F52.0 FOR EQUIPMENT UST FUEL Coi mIENTS 2/523 <br /> W L W W 18 O 73 76 FUEL C-1 4/2023 <br /> W QW j W I 8 FUEL COMIdENTS 5/15/23 <br /> r W I I I xoaess�oa,U.se,v.s <br /> 1 I <br /> W I W W I I W 4 W W SED,ARCH <br /> ► � � W W W W <br /> W <br /> W <br /> W <br /> WI W � � � — � � '. ..✓;' � �j, W W W W W W OF CALF <br /> W W W W W <br /> �W W W l wi m 7 wa 7 m Ii WWWWWWWWWWWWWWWW � 20-016 05-042020 <br /> WI W N J II W W W W W W W �b��j FUEL LINE LEGEND R°recT <br /> W o IS ND o ` 5 <br /> W W <br /> W' W <br /> — <br /> ._ --- — II / W W W W W W W W W W W W W .-- _ — m m o<• oa DEF <br /> W <br /> W W W <br /> W W W <br /> W W W S' �• <br /> r <br /> / U \ DIESEL ENLARGED TRUCK FUEL <br /> VENT LINE SYSTEM SITE PLAN <br /> r1v— <br /> CA-> <br /> •\ <br /> r � Q <br /> .. .,.WWW. . <br /> 20 1! GED TR C FU L SYS EM IT P N � � "� " W" �s<�MaER <br /> SCALE: ,"=,o..o.. FS1.3 <br />