Laserfiche WebLink
ENYIRCNMENTA! BCIEHCEB <br />Arcadis- SLO Reported: 02/27/2023 10:29 <br />735 Tank Farm Rd, Suite 150 Project: Forward Landfill <br />San Luis Obispo, CA 93401 Project Number: 30110749.01 <br />Project Manager: Drew Feucht <br />Volatile Organic Analysis (EPA Method 82606) <br />Quality Control Report - Precision & Accuracy <br />Control Limits <br />Source Source Spike Percent Percent Lab <br />Constituent Type Sample ID Result Result Added Units RPD Recovery RPD Recovery Quals R# <br />QC Batch ID: B160636 <br />Used client sample: <br />N <br />Benzene <br />MS <br />2303825-01 <br />ND <br />25.836 <br />25.000 <br />ug/L <br />103 <br />70-130 <br />1 <br />MSD <br />2303825-01 <br />ND <br />25.766 <br />25.000 <br />ug/L <br />0.3 <br />103 <br />20 <br />70-130 <br />2 <br />Bromodichloromethane <br />MS <br />2303825-01 <br />ND <br />26.134 <br />25.000 <br />ug/L <br />105 <br />70-130 <br />1 <br />MSD <br />2303825-01 <br />ND <br />25.520 <br />25.000 <br />ug/L <br />2.4 <br />102 <br />20 <br />70-130 <br />2 <br />Chlorobenzene <br />MS <br />2303825-01 <br />ND <br />25.020 <br />25.000 <br />ug/L <br />100 <br />70-130 <br />1 <br />MSD <br />2303825-01 <br />ND <br />25.083 <br />25.000 <br />ug/L <br />0.3 <br />100 <br />20 <br />70-130 <br />2 <br />Chloroethane <br />MS <br />2303825-01 <br />ND <br />27.165 <br />25.000 <br />ug/L <br />109 <br />70-130 <br />1 <br />MSD <br />2303825-01 <br />ND <br />26.289 <br />25.000 <br />ug/L <br />3.3 <br />105 <br />20 <br />70-130 <br />2 <br />1,4 -Dichlorobenzene <br />MS <br />2303825-01 <br />ND <br />25.761 <br />25.000 <br />ug/L <br />103 <br />70-130 <br />1 <br />MSD <br />2303825-01 <br />ND <br />25.942 <br />25.000 <br />ug/L <br />0.7 <br />104 <br />20 <br />70-130 <br />2 <br />1,1-Dichloroethane <br />MS <br />2303825-01 <br />ND <br />25.355 <br />25.000 <br />ug/L <br />101 <br />70-130 <br />1 <br />MSD <br />2303825-01 <br />ND <br />25.628 <br />25.000 <br />ug/L <br />1.1 <br />103 <br />20 <br />70-130 <br />2 <br />1,1-Dichloroethene <br />MS <br />2303825-01 <br />ND <br />29.808 <br />25.000 <br />ug/L <br />119 <br />70-130 <br />1 <br />MSD <br />2303825-01 <br />ND <br />34.304 <br />25.000 <br />ug/L <br />14.0 <br />137 <br />20 <br />70-130 <br />Q03 2 <br />Toluene <br />MS <br />2303825-01 <br />ND <br />25.818 <br />25.000 <br />ug/L <br />103 <br />70-130 <br />1 <br />MSD <br />2303825-01 <br />ND <br />25.491 <br />25.000 <br />ug/L <br />1.3 <br />102 <br />20 <br />70-130 <br />2 <br />Trichloroethene <br />MS <br />2303825-01 <br />ND <br />25.935 <br />25.000 <br />ug/L <br />104 <br />70-130 <br />1 <br />MSD <br />2303825-01 <br />ND <br />25.258 <br />25.000 <br />ug/L <br />2.6 <br />101 <br />20 <br />70-130 <br />2 <br />1,2-Dichloroethane-d4 (Surrogate) <br />MS <br />2303825-01 <br />ND <br />10.580 <br />10.000 <br />ug/L <br />106 <br />75-125 <br />1 <br />MSD <br />2303825-01 <br />ND <br />10.700 <br />10.000 <br />ug/L <br />1.1 <br />107 <br />75-125 <br />2 <br />Toluene -d8 (Surrogate) <br />MS <br />2303825-01 <br />ND <br />10.170 <br />10.000 <br />ug/L <br />102 <br />80-120 <br />1 <br />MSD <br />2303825-01 <br />ND <br />10.140 <br />10.000 <br />ug/L <br />0.3 <br />101 <br />80-120 <br />2 <br />4-Bromofluorobenzene (Surrogate) <br />MS <br />2303825-01 <br />ND <br />10.050 <br />10.000 <br />ug/L <br />100 <br />80-120 <br />1 <br />MSD <br />2303825-01 <br />ND <br />10.060 <br />10.000 <br />ug/L <br />0.1 <br />101 <br />80-120 <br />2 <br />Run <br />Run # QC Sample ID <br />QC Type <br />Method <br />Prep Date <br />Date Time <br />Analyst <br />Instrument <br />Dilution <br />1 B160636 -MSI <br />MS <br />EPA -8260B <br />02/23/23 <br />02/24/23 08:34 <br />RCC <br />MS -V14 <br />1 <br />2 B160636-MSD1 <br />MSD <br />EPA -8260B <br />02/23/23 <br />02/24/23 08:57 <br />RCC <br />MS -V14 <br />1 <br />The results in this report apply to the samples analyzed in accordance with the chain of custody document. This analytical report must be reproduced in its entirety. <br />All results listed in this report are for the exclusive <br />use of the submitting <br />party. <br />Pace Analytical assumes no responsibility for <br />report alteration, <br />separation, detachment <br />or third party interpretation. <br />Report ID: 1001401218 <br />4100 Atlas <br />Court Bakersfield, CA 93308 (661) 327-4911 FAX (661) 327-1918 www.pacelabs.com <br />Page 19 of 20 <br />