Laserfiche WebLink
i <br />,ICHAUS7' (AN INFO <br />NIT TAG 1 <br />FAN <br />U <br />NO. <br />1 KEX-1 <br />CFM ESP. <br />1225 0280 1155 <br />RPM <br />0.500 <br />H.P. <br />0.1730 <br />BHP. VOLT <br />115 <br />FLA <br />8.4 <br />WEIGHT <br />(LBS.) <br />62 <br />SONES <br />9.7 <br />FAN UNIT MODEL it <br />DU5OHFA <br />rAN 1.0F'TIOITS <br />FAN <br />UNIT TAG OPTION OTty. - Descr.) <br />NO. <br />1 KEX-1 1 - Low Profile Option - 50. <br />12" 6' <br />14' 6' <br />10' 10' <br />14' 10' <br />VERTICAL SUPPORT <br />MAXIMUM SPACING (FT) <br />DUCT MAXIMUM <br />DIAMETER SPACING (FT) <br />a. tw <br />yr Icy <br />12' 10' <br />14' 10' <br />16. 10' <br />1t1" 10' 20. IT <br />ev iT <br /> 0' 3. <br />3- or 10' 3. 0' 18' 12. <br />3. I. or <br />3. 16, <br />3. 06 or <br />3. 10. <br />3. or 24' <br />CLEARANCE TO COMBUSTIBLES <br />DIAMETER COMBUSTIBLES LIMITED <br />COMBUSTIBLES <br />NON <br />COMBUSTIBLES <br />7 B. 2.16 30 <br />6 160 10' 30 <br />5 30 121 12' 4 30 3.73 <br />3.5 30 425 16' 3 30 4.7e UM 3 30 530 20' 55 30 635 24' <br />3M FIRE BARRIER 2000 PLUS USAGE <br />DUCT <br />DIAMETER <br />DUCT JOINT <br />PERIMETER FT. <br />AVERAGE FT. <br />PER TUBE <br />JOINTS PER <br />TUBE <br />6' 20' <br />6' 24' <br />ADJUST ABLE DUCT <br />OVERLAP - MINIMUM <br />DIAMETER OVERLAP <br /> <br /> <br /> <br />6' IEM <br />20' 10' <br />24. 10' <br />HORIZONTAL SUPPORT <br />MAXIMUM SPACING (FT) <br />DUCT <br />DIAMETER <br />MAXIMUM <br />SPACING (FT) <br />10' <br />10' <br />10' <br />out, <br />No. TAG <br />LINTIAMA(JVIV <br />MODEL LENGTH HOOD RISERIS> <br />uvwx.cso.wyt,. <br />MAX. <br />COOKING <br />TEMP. <br />EXHAUST PLENUM <br />HOOD <br />CONSTRUCTION <br />HOOD CONFIG. <br />TOTAL <br />EXH. CFM <br />END TO <br />END ROW <br />WIDTH LENG. HEIGHT DIA. CFM S.P. <br />1 3347 <br />01 -2 7' 040' Deg. 1225 450 430 4' 14' 1225 -0275' SS <br />Where Exposed ALONE ALONE <br />HOOD <br />HOOD <br />NO. TAG <br />INFORMATION <br />F11.1TR(S> LIGHT(S) UTILITY CABINET(S) <br />FIRE SYSTEM ELECTRICAL SWITCHES FIRE <br />PIPING <br />SYSTEMHANGING <br />HOOD <br />WGHT TYPE OTT. LENGTH EFFICIENCY e 9 <br />MICRONS QTY. TYPE WIRE <br />GUARD LOCATION SIZE TYPE SIZE MODEL * QUANTITY <br />1 SS Baffle with Handles 3 16' 16' 30% 0 NO 220 <br />LBS <br />II" 71 "TM^ 'A Trin kr 9DORRA4 <br />41VVy <br />HOOD <br />NO. TAG <br />V,JyvIlu <br />OPTION <br />1 <br />RIGHT QUARTER END PANEL 23' Top Width, 0' Bottom Width, 23' High 430 IS <br />LEFT QUARTER END PANEL 23' Top 4Adth, 0' Bottom Width, 23' High 430 IS <br />INSULATION FOR BACK OF HOOD <br />TOP ANCHOR <br />GREASE DUCT SPECIFICATION <br />Furnish single-wall factory built, grease duct for use with Type I kitchen hoods, which conforms to the requirements of NFPA-96. <br />Products shall be ETL listed to UL-19713 <br />for venting air and grease vapors from commercial cooking operations as described in NFPA-96. <br />The duct wall shall be constructed of .036 thick type 430 stainless steel and be available in diameters B' through 24". <br />All supports. fan adapters, hood connections, fittings and expansion joints required to install grease duct shall be included. <br />Roof penetrations shall comply with listed clearance to combustibles, see "Clearance to Combustibles' guide for details. <br />The grease duct wit terminate at the fan adapter plate. will be fully welded to the fan adapter plate and the fan adapter plate <br />will be fastened to the curb using a suitably sized fastener provided by others; see page 12 of the installation. Operation and <br />Maintenance Manual" for details. <br />Grease duct joints shall be held together by means of formed vee clamps and sealed with 3M Fire Bonier 2000+. Screws used to secure the vee <br />clamps shall be of the hex-head type with flanged stops and tapered "lead in* threads for easy starting. Nuts shall be retained by means of a <br />free-floating cage to allow easy alignment. <br />Single-Wall Grease Duct shall be installed in accordance with the manufacturer's "Installation, Operation and Maintenance Manual", ETL listing and state and local codes. <br />Grease duct installed outside of the building shall be protected against accidental damage or vandalism. <br />Support vertically installed grease duct from the building structure using rigid structural supports. Anchor supports to the structure by welding or bolting steel expansion <br />anchors or concrete inserts. Support horizontally installed grease duct from the building structure using above method or use Duct Mate, Wire Rope & Clutchers, part <br />numbers WR20 & CL20. 1/2" Threaded rod and saddles may also be used for the support of horizontal grease duct. <br />Fans shall be supported independently from the grease duct sections. Protect grease duct from twisting or movement caused by fan torque or vibration. <br />CAPTIVE-AIRE HOODS ARE <br />BUILT IN COMPLIANCE WITH <br />UL 710 AND NFPA 96 <br />AND ARE RECOGNIZED BY ONE <br />OR MORE OF THE FOLLOWING! <br />ETL SANITATION LISTED <br />ETL LISTED FILE# 3054804-001 <br />JOB Quality Trailers (M & H) 7' 33' BB-2 (Jsted Hood) <br />4109k an .112PPIR <br />togifte ir aria....aEZ. <br />111 Virmwmaimr-r -,== <br />LOCATION Portland, OR, <br />DATE 2/8/2017 <br /> JOB # 2826681 <br />DWG tie 1 <br /> DRAWN BY Sean Elias <br />REV APPENDIWoRagest81149'