Laserfiche WebLink
P/N 12309 <br />P/N 16444 <br />P/N 12506 <br />December 2008 <br /> <br />Section 2 System Components Page 2— 8 <br />Amerex Restaurant Fire Suppression System (EX 4658) <br /> <br />DETECTOR BRACKET ASSEMBLY (P/N 12508) 10" <br />(25.4 cm) <br />Each detector bracket in the Amerex Kitchen Fire <br />Suppression System is comprised of three parts the <br />detector bracket, detector linkage and two EMT fittings. <br />The fusible link is ordered separately. The bracket serves <br />as support for the linkage and is attached to a rigid <br />surface. The linkage supports the fusible link and a <br />continuous cable run under tension. At a predetermined <br />temperature the fusible link will separate, relieving tension <br />on the cable and actuating the system. <br /> <br />Fusible link not included with detector <br />This manual will refer to series and terminal detectors. There is no difference in part numbers or dimensions <br />between series and terminal detectors. A terminal detector is the last or only detector in the network and the <br />cable must be "terminated" there. A series detector is any detector located between the terminal detector <br />and the mechanical release module in the detection network. Cable Terminal End <br />13110 <br />TEST LINKS (P/N 12891) <br />Test links are available for conducting functional tests of the detection <br />system. This device fits the detector linkage in the same manner as the <br />fusible link, is normally placed on the terminal detector and can be cut, <br />simulating a fusible link separating under fire conditions. <br /> <br />) <br /> <br />P/N 12891 <br /> <br />13/64" Dia. <br />Mounting <br />Holes <br />CORNER PULLEY (P/N 12309) <br />The Amerex Kitchen Fire Suppression System uses a "high temperature" <br />corner pulley to change direction of the cable by 90°. This corner pulley <br />may be used in environments with temperatures up to 700°F (371°C). <br />Mounting holes are provided for anchoring the corner pulley where <br />allowed by local codes. <br />CORNER PULLEY (P/N 16444) <br />The Amerex Kitchen Fire Suppression System also use a "high temperature" <br />compression corner pulley to change direction of the cable by 90°. (This <br />compression corner pulley [Brooks Model CP5] allows complete assembly of <br />conduit and corner pulleys prior to installing the cable). <br />PULLEY TEE (P/N 12506) <br />A pulley tee is used to change the direction of two cables by 90°. This <br />device can be used with mechanical gas valves and manual pull stations <br />but not fusible link detectors. It cannot be used where temperatures <br />exceed the range of 32° - 120°F (0° - 49°C). <br />CABLE (P/N 12553) <br />Cable is used to run from the MRM, MRM II or PRM, through conduit and corner pulleys to detectors, <br />mechanical gas valves or manual pull stations. It is 1/16 inch diameter, stainless steel (7 x 7 — 480# tensile <br />strength) — available in 500 foot (152 m) spools (P/N 12553). <br />EYEBOLT SUPPORT (P/N 17520) <br />Eyebolt supplied with one Hex. Nut used to lock the eyebolt into finial <br />position. Eyebolt is used to support bare cable run in plenum of the <br />hood in a Linear Fusible Link Detection System. <br />APPENDIX A - Page 27 of 49