COMPLIANCE INFO_2024
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
3250
>
2300 - Underground Storage Tank Program
>
PR0518288
>
COMPLIANCE INFO_2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/17/2025 3:39:22 PM
Creation date
1/2/2024 1:32:23 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2024
RECORD_ID
PR0518288
PE
2351 - UST FACILITY - 2481 COMPLIANT
FACILITY_ID
FA0013810
FACILITY_NAME
COSTCO WHOLESALE #658
STREET_NUMBER
3250
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95377
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
3250 W GRANT LINE RD TRACY 95377
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
278
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN ) O A Q U I N Environmental Health Department <br /> CP22 - UST FULL Inspection Report <br /> Facility Name: Facility Address: Date: <br /> COSTCO WHOLESALE#658 3250 W GRANT LINE RD TRACY August 20 2024 <br /> 89 CA Health and Safety 2060008-Enhanced leak detection testing performed before the tank is placed in use a OUT ❑R c COS <br /> Code 25290.10) <br /> 90 CA Code of Regulations 2060029-SW piping has been upgraded to continuously monitored DW piping when replacement 1OUT ❑R c COS <br /> 2666(b)(2) or repair needed <br /> 91 CA Health and Safety 2010-Administration/Documentation-General OUT u R c COS <br /> Code 25291(e) <br /> 92 2015-Administrative/Documentation-General Local Ordinance u OUT ❑R c COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS Il,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 12 CA Code of Regulations 2637(e), 2637(f)2010009- Secondary containment test results submitted to the CUPA within <br /> 30 days after the test.. <br /> OBSERVATION: Secondary containment testing was performed on 07/17/2023 and a test report was submitted on <br /> 11/01/2023, 76 days late. <br /> REGULATION GUIDANCE: A copy of the test report must be submitted within 30 days of the tests. <br /> CORRECTIVE ACTION: Take all necessary precautions to ensure testing and submittal of test reports are performed <br /> in a timely manner. <br /> This is a repeat violation(Class 2) Violation. <br /> 51 CA Health and Safety Code 25292.1(a)2030035- UST system is operated to prevent unauthorized release, including <br /> spills and overfills. <br /> OBSERVATION: The fuel filters under the dispensers are not located to allow drips and leaks to drain back into the <br /> UDC. Deflector plates need to be installed at the following UDCs; 1/2,3/4,5/6,7/8,9/10,11112,17/18,19/20,21/22 and <br /> 23/24. <br /> REGULATION GUIDANCE: The underground storage tank system shall be operated to prevent unauthorized releases. <br /> CORRECTIVE ACTION: Immediately provide approved secondary containment for the filters under permit and <br /> inspection by the EHD. <br /> This is(Minor)Violation. <br /> 56 CA Code of Regulations 2716(a-e)2030013-DO inspections completed at least every 30 days and meet all <br /> requirements(TCR 12). <br /> OBSERVATION: Designated operator reports were not signed within the required time frame. -The 11/16/2023 <br /> designated operator report was signed by the owner/operator on 12/13/2023. <br /> REGULATORY GUIDANCE:Within 48 hours of the completion of the designated UST operator visual inspection,the <br /> designated operator shall sign and provide the owner or operator with a copy of the inspection report. Within 72 hours <br /> of being provided a signed copy of the report,the owner or operator shall provide a description of each corrective action <br /> taken or to be taken and shall sign and date the report, acknowledging the identified compliance issues. <br /> CORRECTIVE ACTION: Ensure all designated operator inspection reports are completed and signed within the <br /> required time frame in the future. <br /> This is(Minor)Violation. <br /> FA0013810 PRO518288 SCO01 08/20/2024 <br /> EHD Rev.12/06/2021 Page 5 of 6 CP22-UST FULL OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 952051 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />