Laserfiche WebLink
Q �auiNi j SAN J OA Q U I N Environmental Health Department <br /> PP <br /> �0��,,_,, <br /> "' ' `, ; ` l COUNTY Jasjit Kang , REHS , Director <br /> °� L , F_oRP ' Greatness yroihere . Muniappa Naidu, REHS, Assistant Director <br /> �� vs <br /> PROGRAM COORDINATORS <br /> Jeff Carruesco , REHS , RDI <br /> Willy Ng , REHS <br /> Steven Shih , REHS <br /> Elena Manzo , REHS <br /> Natalia Subbotnikova , REHS <br /> February 29 , 2024 <br /> Carrie Miller <br /> Elite IV Contractors <br /> 2535 Wigwam Dr <br /> Stockton , CA 95205 <br /> carrie@eliteiv . com <br /> Re : Arco Station #83560 SR0087756 <br /> 2908 W. Benjamin Holt Dr , Stockton , CA 95207 <br /> The San Joaquin County Environmental Health Department ( EHD) has completed the review of the <br /> application for a permit to do the following on the underground storage tank ( UST) system at the above <br /> noted address : <br /> • replace the 87 - 1 , 87 -2 , and 91 drop tube with shut- off valve (flapper) <br /> The permit has been approved with the following conditions : <br /> 1 . Contact the local fire district , the San Joaquin Valley Air Pollution Control District , and the local <br /> community development department for any applicable permits and requirements . <br /> 2 . Any changes in information and scope of work must be submitted to EHD for written approval <br /> prior to commencing work . All new submittals supersede previous ones . <br /> 3 . Email notification to ustRsjgov . org to arrange the following inspection appointments . <br /> All appointments must be scheduled at least 48 hours in advance . <br /> a . Verification of overfill prevention : Measurement of drop tubes to verify 95% tank volume shut <br /> off, verification of external audible/visual alarm activation when tank is 90 % full , or other <br /> approved method . Ensure that all pertinent tank charts and calculations are available for <br /> review at the time of inspection . <br /> b . Verification that ball float(s ) , if installed , do not interfere with the installed flapper valve . <br /> The facility cannot receive fuel in the 87 -1 , 87-2 , and 91 tank prior to the EHD inspection and <br /> approval . <br /> 4 . Any individual performing the work of a service technician must possess , or work under the direct <br /> and personal supervision of an individual physically present at the work site at all times while <br /> work is being performed who possesses , all of the following : <br /> • One of several permissible valid , current contractor licenses issued by the CSLB <br /> • A current California UST Service Technician certificate issued by the ICC <br /> • A valid , current certificate of training from the manufacturer(s ) of the component ( s) being <br /> tested , or the developer of the testing equipment or test method (s) being used <br /> 5 . Individuals working under the direct supervision of a qualified UST service technician must , at a <br /> minimum , be employed by the person with the CSLB license and possess all manufacturer <br /> certificates of training for the equipment on which they are working . <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 1 T 209 468-3420 1 F 209 464 -0138 1 www. sjgov . org/ehd <br />