Laserfiche WebLink
SAN J O A R N Environmental Health Department <br /> i y �V <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> JOES TRAVEL PLAZA 15600 S HARLAN RD, LATHROP January 23, 2024 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 208 CCR 2716(a-e) Failure to comply with the designated operator inspection requirements. <br /> 1). OBSERVATION:The designated operator failed to visually inspect the 87 slave spill container for leaks,water, <br /> or debris during the 2/23/2023,4/21/2023 and 5/19/2023 visual inspection. <br /> REGULATION GUIDANCE: During the inspection, the designated operator shall visually inspect all spill containers, <br /> fill pipes,fill caps, and UDC sumps, and any tank top sump that had an alarm for which there is no record of a <br /> service visit,for damage, and for the presence of leaks,water, or debris, and check that the sensors are located <br /> properly. <br /> CORRECTIVE ACTION: Ensure that designated operators performing inspections at this facility are inspecting all of <br /> the required areas and noting it on the on the reports. <br /> -------------------------------------------------------------------------------------------------------------------------------------------------------- <br /> ----------------------------------------------------------------------------- <br /> 2). OBSERVATION:The 11/30/2023 designated operator report was signed by the owner/operator on 11/30/2023, <br /> the owner/operator failed to provide explanation of follow-up actions in section V that will be taken for the statement <br /> provided by the DO in section III. <br /> REGULATORY GUIDANCE:Within 48 hours of the completion of the designated UST operator visual inspection, <br /> the designated operator shall sign and provide the owner or operator with a copy of the inspection report. Within 72 <br /> hours of being provided a signed copy of the report,the owner or operator shall provide a description of each <br /> corrective action taken or to be taken and shall sign and date the report, acknowledging the identified compliance <br /> issues. <br /> CORRECTIVE ACTION: Ensure to provide follow up actions on compliance issues stated on all designated <br /> operator inspection reports . <br /> This is a repeat violation, Class II. <br /> 214 CCR 2712 Failure to comply with UST operating permit conditions. <br /> OBSERVATION: The facility is not in compliance with the written conditions of the operating permit.The <br /> owner/operator/contractor Williams Service&repairs Inc replaced the 91 red Jacket main seal O' RING and <br /> tested good and checked the 87 slow flow rate on 12/5/2023 without providing notification to EHD. <br /> REGULATION GUIDANCE: The owner and operator of underground storage tank(UST)systems shall comply with <br /> all requirements of the permit issued for the operation of the UST system. <br /> CORRECTIVE ACTION: Immediately take all necessary actions to notify EHD, ust@sjgov.org for all repairs <br /> including emergency repairs. <br /> This is a minor violation. <br /> Overall Inspection Comments: <br /> FA0000174 PR0231585 SCO01 01/23/2024 <br /> EHD 23-01 Rev.12/06/2021 Page 5 of 6 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />