My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
I
>
INTERNATIONAL
>
1124
>
1600 - Food Program
>
PR0548691
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/3/2024 2:29:17 PM
Creation date
1/3/2024 2:24:21 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0548691
PE
1617
FACILITY_ID
FA0027447
FACILITY_NAME
MOUNTAIN HOUSE CHEVRON
STREET_NUMBER
1124
Direction
N
STREET_NAME
INTERNATIONAL
STREET_TYPE
PKWY
City
TRACY
Zip
95377
CURRENT_STATUS
01
SITE_LOCATION
1124 N INTERNATIONAL PKWY
P_LOCATION
03
QC Status
Approved
Scanner
SJGOV\ymoreno
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
198
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Master Specification: Model SLN <br />JOB NAME ENGINEER <br />REPRESENTATIVE CONTRACTOR <br />GENERAL <br />Provide a quantity of Solar water heater(s) Model No. as manufactured by HUBBELL <br />Electric Heater Co., Stratford, CT. The entire unit is to be complete with all operating controls and is ready for plumbing service <br />connections. The tank shall be all welded steel commercial construction designed for 150 psi working pressure and contain <br />gallons of storage. The tank is to be lined with seamless Hydrastone cement to a minimum thickness of 1/2" on 100% <br />of all interior tank surfaces and does not require any type of anodic protection. The tank shall be fabricated with non-ferrous <br />copper-silicon threaded tappings and non-ferrous inlet and outlet piping for maximum corrosion resistance. Steel tank <br />tappings shall not be acceptable. The entire tank is to be insulated with a minimum of 2" (ElOptional Specification: 3") thick <br />polyurethane foam insulation and exceed the latest ASHRAE standard for stand-by heat loss. The complete heater shall be <br />supplied with a high impact colorized composite protective jacket which cannot rust or corrode and does not require painting. <br />The unit shall bear the UL listing mark certifying the entire water heater. <br />The cold water inlet shall be 3/4" Female NPT (I:Optional Specification: 11/2" Male NPT) and include a non-corrosive strata- <br />flow diffuser which prevents incoming cold water from mixing too rapidly-with hot water in the tank. A 3/4" hose connection <br />drain is supplied. The hot water outlet connection shall be 3/4" Male NPT (00ptional Specification: 11/2" Male NPT) and shall <br />include a factory installed built-in heat trap to prevent water from radiating through the piping during stand-by periods. A <br />separate 3/4" Female NPT tapping is to be provided for relief valve installation. An ASME rated automatic reseating combination <br />temperature and pressure safety relief valve set at 150 psi and 210°F shall be factory supplied. <br />HEATING COIL <br />The tank shall be supplied with a heating coil which transfers heat from the solar panel system to the domestic <br />water. Solar panel water shall be in the tubes, and domestic water in the tank. The heating coil shall be of single wall <br />(I:Optional Speci ication: double wall) copper construction for maximum heat transfer efficiency and coil longevity. The <br />heating coil shall be fully removable from the tank to allow for periodic inspection and maintenance without the need to move or <br />lift the storage tank from its installed position. A mounting clip and immersion thermowell are supplied for installation of a <br />thermistor (by others) for sensing the water temperature in the tank. <br />El OPTION - BACK-UP HEATER <br />The Solar water hAter will be supplied with a back-up heater. The back-up heater shall be a single electric immersion <br />heating element (UOptional Specification: 119 gallon models only: a dual upper and lower element) rated at KVV <br />each and designed to operate at volts phase Hz with all necessary operating controls factory <br />mounted wired and tested. The heating element(s) shall be copper or incoloy sheath electric immersion type sized to obtain the <br />rated recovery. Water temperature shall be controlled through an adjustable 110-170°F snap action surface thermostat. An <br />over-temperature manual reset Hi-Limit shall be factory installed to disconnect all conductors to the heating element in the <br />event of an over-temperature condition in the pressure vessel. <br />WARRANTY <br />The water heater manufacturer shall warranty all electrical components against defects in workmanship and material for a <br />period of one (1) year from date of start-up, and the pressure vessel including the heating coil for a full seven (7) years Non Pro- <br />Rated for residential applications and five (5) years for commercial applications from date of start-up, provided that the unit is <br />started within three (3) months of date of shipment and installed and operated within the scope of the tank design and <br />operating capability. Each water heater shall be shipped with a complete set of installation and operating instructions including <br />spare parts list and approved drawings. <br /> <br />HthbEfir. MADE IN THE <br />Committed to continuous improvement_ <br />Continuing research results in product Improvement; therefore specifications are subject to USA <br />change without notice. For the most updated information, consult the factory directly. <br />111 <br />ISO 9001 <br />The Electric Heater Company • P.O. Box 288 • Stratford, 01 06615-0288 • Phone: 203-378-2659 • Fax: 203-378-3593 <br />infoghubbellheaters.com • www.hubbellheaters.com <br />Rev A
The URL can be used to link to this page
Your browser does not support the video tag.