Laserfiche WebLink
15 May 2019 <br />AGE Project No. 14-3002 <br />Page 13 of 17 <br />• Barium, copper, molybdenum, selenium, vanadium and zinc were detected in the <br />groundwater samples analyzed at maximum concentrations of 0.480 mg/l, <br />0.161 mg/l, 0.246 mg/l, 0.178 mg/l, 0.609 mg/l, and 0.070 mg/l. Additionally, <br />chromium was detected in the groundwater sample collected from B6 at a <br />concentration of 0.018 mg/l. Except for selenium detected in B1, all metal <br />concentrations were below their respective MCLs and all metal concentrations <br />were below hazardous waste limits (Table 5). <br />• Hexavalent chromium was detected in the groundwater samples collected from <br />B6, B13, B16, B23, B28 and B31 at concentrations ranging from 0.93 micrograms <br />per liter (µg/l) in B13 to 8.4 µg/l in B6. Hexavalent chromium concentrations were <br />below the last established MCL of 10 µg/l (2014). However, as of 2017, there is no <br />established MCL for hexavalent chromium. Also, the concentrations were <br />significantly below the hazardous waste limit (Table 5). <br />• SVOCs, PAHs, PCBs, and VOCs were not detected above laboratory reporting <br />limits in any of the groundwater samples analyzed (Table 6). <br />• Except for TPH-g detected at the laboratory reporting limit of 50 µg/l in the <br />groundwater sample collected from B40, TPH were not detected above laboratory <br />reporting limits in any of the groundwater samples analyzed (Table 6). <br />• Dioxin/Furans were detected in the groundwater sample collected from B35 at a <br />TEQ concentration of 2.10 picograms per liter (pg/l). Dioxin/Furans were not <br />detected above laboratory reporting limits in the groundwater samples collected <br />from B13 and B16. The concentration detected in B35 was significantly below the <br />MCL of 30 pg/l for dioxin/furans and the congener 2,3,7,8-TCDD was not detected <br />in the sample (Table 6). <br />• Except for the groundwater sample collected from B40, nitrate as nitrogen and <br />nitrate as nitrate were detected in the groundwater samples at maximum <br />concentrations of 36 mg/l nitrate as nitrogen and 160 mg/l nitrate as nitrate in B28. <br />Nitrate as nitrogen concentrations detected in B28 and B35 were above the MCL <br />of 10 mg/l; and nitrate as nitrate concentrations detected in B23, B28, B31 and <br />B35 were above the MCL of 45 mg/l. <br />• Ammonia was detected in samples collected from B13, B16, B23, B28, B31, B35 <br />and B40 at concentrations ranging from 0.22 mg/l in B13 to 2.8 mg/l in B28. There <br />is no established MCL for ammonia. However, environmental limits for ammonia <br />in surface water in the United States range from 0.25 mg/l to 32.5 mg/l (Oregon <br />Public Health Division). <br />• TDS was detected in the water samples at concentrations ranging from 705 mg/l <br />in B16 to 2,590 mg/l in B1. The concentrations were above the secondary MCL of <br />500 mg/l. <br /> <br />Analytical results of groundwater samples are summarized in Tables 5 through 7. The <br />laboratory reports (listed in Section 5.3.), QA/QC reports and chain of custody forms are