Laserfiche WebLink
Environmental Health Department <br />Time In: <br />12:07 pm <br />11:39 am <br />Time Out: <br />Program Element: 3611 - PUBLIC POOL/SPA - PRIMARY <br />Telephone: (209) 346-0229 Owner/Operator: MENDOZA, GUADALUPE <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 1347 HOLLY DR, TRACY 95376 <br />Date: 07/27/2023Name of Facility: PARKVIEW APARTMENTS <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #8 Pool and Deck Lighting <br />OBSERVATIONS: The pool light is not functioning. Repair/replace the pool light by 2 weeks. <br />CALCODE DESCRIPTION: Pools used at night shall be equipped with underwater light fixtures that provide complete illumination of the <br />pool. When a pool is used at night, pool deck and emergency egress areas shall be provided with lighting. If underwater or deck lighting is <br />not operational, the pool operator shall post a sign in 4-inch letters stating "NO USE OF POOL ALLOWED AFTER DARK" and shall <br />secure the pool area and not permit any use of the pool after dark. (3115B) <br /> #13 Cyanuric Acid Concentration <br />OBSERVATIONS: The cyanuric acid level of the pol is greater than100ppm. Take action to reduce the cyanuric acid level to <br />less than 100ppm. Correct by next season. <br />CALCODE DESCRIPTION: Pool operator shall maintain cyanuric acid concentration between 0.0 ppm and 100 ppm. (CCR 65530) <br /> #35 Flow Meters <br />OBSERVATIONS: The flowmeter is not functioning. Repair the flowmeter to proper function by 2 weeks. <br />CALCODE DESCRIPTION: Flow meters shall be provided on each recirculation system and shall be installed in accordance with <br />manufacturer's specifications. (CBC 3125B) <br />OVERALL INSPECTION NOTES AND COMMENTS <br />OBSERVATIONS <br />Flow rate:gpm <br />pH: <br />Chlorine:ppm <br />Cyanuric acid:ppm <br />Temp:º F 0 <br />7.4 <br />4.2 <br />>100 Combined chlorine:ppm0.2 <br />NOTES <br />Influent: 12 <br />Effluent: 3 <br />No signature obtained <br />Report typed in the office 3:24p-3:31p <br />Page 1 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0002549 PR0360427 SC001 07/27/2023 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD