Laserfiche WebLink
Environmental Health Department <br />Time In: <br />11:33 am <br />11:03 am <br />Time Out: <br />Program Element: 3611 - PUBLIC POOL/SPA - PRIMARY <br />Telephone: Owner/Operator: KAITZ PROPERTY SERVICE <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 225 E GRANT LINE RD, TRACY 95376 <br />Date: 07/27/2023Name of Facility: CABRILLO GARDENS APARTMENTS <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #10 Disinfectant Residual MAJOR <br />OBSERVATIONS: The chlorine level of the pool is 0.2 ppm. Immediately increase the chlorine level of the pool to 2.0 to <br />10.0ppm or face closure. <br />Liquid chlorine added: re-checked chlorine level: 3.8ppm <br />Corrected on site. <br />CALCODE DESCRIPTION: Public pools, when open or in use, shall be disinfected continuously by approved chemicals and shall maintain <br />the following concentrations: 1.0 ppm to 10.0 ppm free chlorine without cyanuric acid, 2.0 ppm to 10.0 ppm free chlorine with cyanuric acid <br />or 2.0 ppm bromine. Spas, wading pools, and spray grounds shall maintain the following concentrations: 3.0 ppm to 10.0 ppm free <br />chlorine or 4.0 ppm bromine. (CCR 65529) <br /> #3 Safety Signs <br />OBSERVATIONS: The safety signage lacks the facility address on it. The facility name on the safety signage is faded. Write <br />in this info on the safety signage today. <br />CALCODE DESCRIPTION: Pool operator shall keep safety signs well maintained. (CCR 65535) Safety signs shall have clearly legible <br />letters or numbers not less than 4 inches high, unless otherwise specified. Safety signs shall be affixed to a wall, pole, gate, or similar <br />permanent structure in a location visible to all pool users, unless otherwise specified. (CBC 3120B) <br /> #8 Pool and Deck Lighting <br />OBSERVATIONS: The pool light is on a photocell - unable to verify the pool light and GFCI's proper function. Verify the pool <br />light and GFCI are functioning properly. <br />CALCODE DESCRIPTION: Pools used at night shall be equipped with underwater light fixtures that provide complete illumination of the <br />pool. When a pool is used at night, pool deck and emergency egress areas shall be provided with lighting. If underwater or deck lighting is <br />not operational, the pool operator shall post a sign in 4-inch letters stating "NO USE OF POOL ALLOWED AFTER DARK" and shall <br />secure the pool area and not permit any use of the pool after dark. (3115B) <br />OVERALL INSPECTION NOTES AND COMMENTS <br />OBSERVATIONS <br />Flow rate:gpm <br />pH: <br />Chlorine:ppm <br />Cyanuric acid:ppm <br />Temp:º F 70 <br />7.2 <br />0.2 <br /><30 Combined chlorine:ppm0.4 <br />Page 1 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0003032 PR0360317 SC001 07/27/2023 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD