Laserfiche WebLink
Franklin Fueling Systems <br /> P " <br /> DEFENDER SERIES@ <br /> OVERFILL PREVENTION VALVE <br /> F <br /> A <br /> AAA <br /> iE <br /> The Defender Series@ Overfill Prevention Valve ( OPV) prevents the overfill of <br /> an underground storage tank during a gravity-fed product delivery. It employs T <br /> a revolutionary magnetically-coupled actuator system to provide positive <br /> shutoff. This unique method of shutoff eliminates any penetrations in the <br /> valve , making it both vapor and leak tight. This also allows for remote <br /> compliance testing of the primary functionality at grade level without having U <br /> to remove the OPV from the tank. ' <br /> Drop Tube <br /> Adapter <br /> HIGHLIGHTS SPECIFICATIONS <br /> • Magnetic coupler actuates the interior primary flapper Approvals & Certifications <br /> assembly and secondary shut-off valve when the float rises <br /> outside of the valve, eliminating valve body penetrations and • CARB certified , VR- 101 -U ( FFS ) and VR- 102 (OPW°)% <br /> any potential product or vapor leak points. • ATEX 2014/34/EU approved . <br /> • After cutting to length in the field , the upper drop tube is EN13616 certified . <br /> roll-crimped onto a top adapter outfitted with two 0-rings and • KIWA BRL-1<636/03 certified . <br /> then threaded onto the top of the valve body, eliminating the <br /> need for drilling, rivets, epoxy, and flaring tools. • UL 2583 listed and ULc listed, MH21090. <br /> • Bottom drop tube is cut in the field and threaded onto the For all vapor control and liquid control products covered <br /> bottom of the valve ensuring straight installation . by UL 2583 automotive fuels, only those fuels formulated <br /> • The roll -crimp/thread method of installing drop tubes ensures in accordance with 40CFR80, " Regulation of Fuels and <br /> proper alignment of the drop tubes with the rest of the OPV Fuel Additives, " and meeting the following ASTM fuel <br /> assembly, making installation and removal of the entire specifications and blend limits: <br /> assembly smooth . • ASTM D975 diesel with or without biodiesel blends up <br /> • Damaged drop tubes can be easily replaced instead of having to 5% ( 65) <br /> to purchase an entire new assembly. • ASTM D7467 diesel with biodiesel blends between 6% <br /> • Fully compatible with gas, gas/alcohol blends, diesel, and . 20% ( 136 - B20) <br /> Biodlesel . • ASTM D4814 gasoline with ethanol blends up to 10% <br /> • Compatible with industry standard 4 " drop tubes allowing ( 1110) <br /> retrofit into existing installations . . ASTM D4814 and ASTM D5798 mid-range ethanol/ <br /> • The entire OPV assembly remains within the 4 " inner gasoline blends of ( Ell -50) <br /> diameter of the riser preventing interference with other . ASTM D5798 high- range ethanol/gasoline blends <br /> tank components and also allowing removal even while ( E51 -83)-Commercially sold as E85 <br /> the tank is full . . Isobutanol Fuel Blends ( max iBul6) of ASTM D4814 <br /> • Actuates in both low- and high -flow applications and Gasoline ( EO ) and ASTM D7862 Butanol (2-methykl - <br /> functions within a broad range of flow rates from propanol isomer) <br /> 25 gpm to 370 gpm ( 95 Ipm to 1 , 400 Ipm ) and higher. <br /> • In addition to UI 2583 listed fuels, the following fuels are <br /> The remote testing tool allows for remote testing of the <br /> primary functionality without having to remove the OPV also compatible: <br /> from the riser. • Biodiesel up to 5% B5 <br /> • Biodiesel up to 20% B20 <br /> • Biodiesel at 97%- 100% 1399/13100 <br /> • All ASTM Biofuel blends <br /> • Alcohol, gas, biofuel compatible ( E-85, gasoline and <br /> biodiesel) models come with hard coated anodized drop <br /> tubes for full compatibility. <br />