Laserfiche WebLink
To: Woldearegay, Shewit<stwoldearegav@sigov.org> <br /> Cc: Emily Crain <emily@bzmaint.com>; Rivera, Stacy [EHD] <srivera@sigov.org> <br /> Subject: RE: Inspection Report-SR0087167-7700 Moreland St, Stockton <br /> The dispensers were Gilbarco to Gilbarco—so no conversion frames were used as they are the same footprint. <br /> Deflector plates were installed. <br /> Also—we need to replace the 87 and 91 OPW drop tubes at this site to complete the vapor testing. The flappers are <br /> leaking. Can we add these drop tubes to the current open permit?I have attached the drop tube cut sheets,let me know <br /> what else I need to send you. <br /> We will be on site on Friday 1/26 to make repairs and finish the vapor. We can complete the sensor functionality testing <br /> and overfill testing(of new drop tubes)while we are on site. <br /> Margaret <br /> From:Woldearegay, Shewit<stwoldearegav@sigov.org> <br /> Sent:Tuesday, December 5, 2023 2:45 PM <br /> To: Margaret Smith <msmith@bzmaint.com>; s harpreetl3@yahoo.com; Demitris kaplanis<zeuskaplanis@yahoo.com> <br /> Cc: Emily Crain <emily@bzmaint.com>; Rivera, Stacy [EHD] <srivera@sigov.org> <br /> Subject: RE: Inspection Report-SR0087167-7700 Moreland St, Stockton <br /> Hi Margaret, <br /> Thank you for the email.The sensor functionality testing was not completed on 11/13/2023 because a cold start was not <br /> performed. However, the following inspections are still missing and need to be completed to finalize the permit. When I <br /> asked the service technician about the remaining inspections that were documented in the permit, he mentioned that <br /> the office would schedule them. If dispensers with conversion frames and deflector plates were not installed and a cold <br /> start was unnecessary, please provide an amended scope of work. If dispensers with conversion frames and deflector <br /> plates were installed, please schedule the following inspections as they are required to complete the permit: <br /> -Sensor functionality testing <br /> -Visual inspection of piping within the dispenser <br /> -Verification that the dispenser footprints are contained by the under-dispenser containment sumps (UDCs) <br /> Kind Regards, <br /> Shewit Woldearegay <br /> Environmental Health Specialist <br /> San Joaquin County Environmental Health Department <br /> 1868 E. Hazelton Avenue,Stockton, CA 95205 <br /> Phone: (209) 616-3063 1 E-mail: stwoldearegav@sieov.org <br /> Free CUPA training classes: https://www.sogov.org/department/envhealth/ <br /> ***I am out of the office every other Friday as follows: December 8, 22, 25 January 1,5, 15 19 February 2, 12, 16, <br /> 19, 26-29 <br /> From: Margaret Smith <msmith@bzmaint.com> <br /> Sent:Tuesday, December 5, 2023 2:14 PM <br /> To:Woldearegay, Shewit<stwoldearegav@sieov.org>; s harpreetl3@vahoo.com; Demitris kaplanis <br /> 4 <br />