Laserfiche WebLink
To: Woldearegay, Shewit <stwoldearegav@sigov.org> <br />Cc: Emily Crain <emily@bzmaint.com>; Rivera, Stacy [EHD] <srivera@sigov.org> <br />Subject: RE: Inspection Report - SR0087167 - 7700 Moreland St, Stockton <br />The dispensers were Gilbarco to Gilbarco — so no conversion frames were used as they are the same footprint. <br />Deflector plates were installed. <br />Also — we need to replace the 87 and 91 OPW drop tubes at this site to complete the vapor testing. The flappers are <br />leaking. Can we add these drop tubes to the current open permit? I have attached the drop tube cut sheets, let me know <br />what else I need to send you. <br />We will be on site on Friday 1/26 to make repairs and finish the vapor. We can complete the sensor functionality testing <br />and overfill testing (of new drop tubes) while we are on site. <br />Margaret <br />From: Woldearegay, Shewit <stwoldearegav@sigov.org> <br />Sent: Tuesday, December 5, 2023 2:45 PM <br />To: Margaret Smith <msmith@bzmaint.com>; s harpreetl3@yahoo.com; Demitris kaplanis <zeuskaplanis@yahoo.com> <br />Cc: Emily Crain <emily@bzmaint.com>; Rivera, Stacy [EHD] <srivera@sigov.org> <br />Subject: RE: Inspection Report - SR0087167 - 7700 Moreland St, Stockton <br />Hi Margaret, <br />Thank you for the email. The sensor functionality testing was not completed on 11/13/2023 because a cold start was not <br />performed. However, the following inspections are still missing and need to be completed to finalize the permit. When I <br />asked the service technician about the remaining inspections that were documented in the permit, he mentioned that <br />the office would schedule them. If dispensers with conversion frames and deflector plates were not installed and a cold <br />start was unnecessary, please provide an amended scope of work. If dispensers with conversion frames and deflector <br />plates were installed, please schedule the following inspections as they are required to complete the permit: <br />- Sensor functionality testing <br />- Visual inspection of piping within the dispenser <br />- Verification that the dispenser footprints are contained by the under -dispenser containment sumps (UDCs) <br />Kind Regards, <br />Shewit Woldearegay <br />Environmental Health Specialist <br />San Joaquin County Environmental Health Department <br />1868 E. Hazelton Avenue, Stockton, CA 95205 <br />Phone: (209) 616-3063 1 E-mail: stwoldearegav@sieov.org <br />Free CUPA training classes: https://www.s9gov.org/department/envhealth/ <br />***I am out of the office every other Friday as follows: December 8, 22, 25 1 January 1, 5, 15 19 1 February 2, 12, 16, <br />19,26-29 <br />From: Margaret Smith <msmith@bzmaint.com> <br />Sent: Tuesday, December 5, 2023 2:14 PM <br />To: Woldearegay, Shewit <stwoldearegav@sieov.org>; s harpreetl3@vahoo.com; Demitris kaplanis <br />