My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2024
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MORELAND
>
7700
>
2300 - Underground Storage Tank Program
>
PR0231819
>
COMPLIANCE INFO_2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/14/2025 10:54:52 AM
Creation date
1/18/2024 2:31:32 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2024
RECORD_ID
PR0231819
PE
2351 - UST FACILITY - 2481 COMPLIANT
FACILITY_ID
FA0003732
FACILITY_NAME
GAVINKO PETROLEUM*
STREET_NUMBER
7700
STREET_NAME
MORELAND
STREET_TYPE
ST
City
STOCKTON
Zip
95212
APN
13003010
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\lsauers1
Supplemental fields
Site Address
7700 MORELAND ST STOCKTON 95212
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
187
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r-� SAN AQN Environmental Health Department <br /> P . <br /> n <br /> COUNTY Jasjit Kang , REHS , Director <br /> 01 Greatness grows here . Muniappa Naidu , REHS , Assistant Director <br /> PROGRAM COORDINATORS <br /> Jeff Carruesco , REHS , RDI <br /> Willy Ng , REHS <br /> Steven Shih , REHS <br /> Elena Manzo , REHS <br /> Natalia Subbotnikova , REHS <br /> January 25 , 2024 <br /> MARGARET SMITH <br /> BZ MAINTENANCE <br /> PO BOX 933 <br /> SACRAMENTO , CA 95691 <br /> msmith (a� bzmaint . com <br /> Re : GAVINKO PETROLEUM Amended SR0087167 <br /> 7700 MORELAND ST <br /> STOCKTON , CA 95212 <br /> The San Joaquin County Environmental Health Department ( EHD ) has completed the review of the <br /> application for a permit to do the following on the underground storage tank ( UST ) system at the above <br /> noted address : <br /> • Replace dispensers with conversion frame installation <br /> • Deflector plate installation <br /> • Cold start the monitoring panel <br /> • Replace 87 and 91 drop tubes with shut- off valves (flappers ) <br /> The permit has been approved with the following conditions : <br /> 1 . Contact the local fire department and the San Joaquin Valley Air Pollution Control District for any <br /> applicable permits and requirements . <br /> 2 . Any changes in information and scope of work must be submitted to EHD for approval prior to <br /> commencing work . All new addenda supersede the previous ones . <br /> 3 . Provide written notification to ust sjgov . org to arrange the following inspection appointments ( a 48 - <br /> hour notice is required for inspection appointments ) . <br /> a . Sensor functionality : Functionality of the monitoring system must be verified to ensure that <br /> monitoring has been restored to meet the requirements of Title 23 California Code of <br /> Regulations and the Health & Safety Code . A copy of the alarm history shall be printed prior to <br /> performing the cold start of the monitoring panel , and made available at the time of EHD <br /> inspection . <br /> b . Verification of the dispenser footprints contained by the under dispenser containment sumps <br /> ( UDCs ) . Any potential leaks from piping and fuel filters must drain directly into UDCs . <br /> c . Visual inspection of the piping within the dispensers <br /> d . Verification of overfill prevention : Measurement of drop tubes to verify 95 % tank volume <br /> shut off , verification of external audible /visual alarm activation when tank is 90 % full , or <br /> other approved method . Ensure that all pertinent tank charts and calculations are available <br /> for review at the time of inspection . <br /> e . Verification that ball float ( s ) , if installed , do not interfere with the installed flapper valve . <br /> 4 . Any individual performing the work of a service technician must meet the following qualifications : <br /> a . Possess or be employed by a person who possesses one of several permissible valid , current <br /> contractor ' s licenses issued by the Contractors State License Board ( may be issued to the <br /> installation company ) , or a Tank Tester ' s license issued to the individual by the State Water <br /> Board <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 1 T 209 468 - 3420 1 F 209 464 - 0138 1 www . sjgov . org / ehd <br />
The URL can be used to link to this page
Your browser does not support the video tag.