Laserfiche WebLink
Environmental Health Department <br />Underground Storage Tank Program Inspection Report <br />Date: <br />January 23, 2024 <br /> Facility Address: <br /> 6425 N PACIFIC AVE, STOCKTON <br /> Facility Name: <br /> SAFEWAY FUEL CENTER #2707 <br />Single-Walled Non-Pressurized Piping <br /> 404 □ V □ R □ COSFailure to conduct 0.1 gph test on single-walled gravity piping biennially or post repair (pre-1984)CCR 2643(e), 2661(f) <br />Other Violations <br /> 2010 □ V □ R □ COSUnlisted General violation See below <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br /> 208 CCR 2716(a-e) Failure to comply with the designated operator inspection requirements. <br />OBSERVATION: The designated operator failed to check and note the correct test dates for the Overfill Prevention <br />Equipment on the designated operator inspection reports. The correct date for Overfill Prevention Equipment testing <br />is 02/22/2023. The test date was reset following replacement of overfill prevention equipment. <br />REGULATION GUIDANCE: During the inspection, the designated operator shall check that all required testing and <br />maintenance for the UST system have been completed and document the dates they were done. <br />CORRECTIVE ACTION: Ensure that designated operators performing inspections at this facility are including all of <br />the required information on the reports. <br />This is a repeat violation, Class II. <br /> 302 CCR 2630(d), 2641(a) Leak detection equipment not installed/maintained/located to detect leaks at earliest <br />opportunity. <br />OBSERVATION: Test boots on the piping were not pulled back in the 87, 91 and Diesel Fill sumps. Schrader valves <br />were open, but pointed up and not positioned in a way that leaks will be detected at the earliest opportunity. <br />REGULATION GUIDANCE: Monitoring equipment shall be maintained to be able to detect a leak at the earliest <br />possible opportunity. <br />CORRECTIVE ACTION: This violation was corrected on site. <br />--------------------------------------------------------------------------------- <br />OBSERVATION: Test boots on the piping in all the UDCs were not pulled back. Hoses attached to the boots were <br />looped upward and not positioned in a way that leaks will be detected at the earliest opportunity. <br />REGULATION GUIDANCE: Monitoring equipment shall be maintained to be able to detect a leak at the earliest <br />possible opportunity. <br />CORRECTIVE ACTION: Immediately contact a properly licensed, trained, and certified contractor to ensure that any <br />releases in the piping in the UDCs will be detected at the earliest opportunity. <br />This is a repeat violation, Class II. <br />FA0002409 PR0231211 SC001 01/23/2024 <br />EHD 23-01 Rev. 12/06/2021 Underground Storage Tank Program OIRPage 4 of 5 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD