My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2023
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TURNER
>
200
>
3600 - Recreational Health Program
>
PR0360023
>
COMPLIANCE INFO_2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/31/2024 4:37:04 PM
Creation date
1/31/2024 4:20:39 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3600 - Recreational Health Program
File Section
COMPLIANCE INFO
FileName_PostFix
2023
RECORD_ID
PR0360023
PE
3611
FACILITY_ID
FA0000656
FACILITY_NAME
CHATEAU APARTMENTS LODI
STREET_NUMBER
200
Direction
W
STREET_NAME
TURNER
STREET_TYPE
RD
City
LODI
Zip
95240
APN
04112008
CURRENT_STATUS
01
SITE_LOCATION
200 W TURNER RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
3
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
`'.. ll � � �A�] I N Environmental Health Department <br /> `- Irl +lJ <br /> L.. v•:v COUNTY <br /> .r{ � 7fa�p[r+85S grows hire, Time In: 10.40 am <br /> Time Out: 11:16 am <br /> Swimming Pool Official Inspection Report <br /> Name of Facility: CHATEAU APARTMENTS LODI Date: 08/01/2023 <br /> Address: 200 W TURNER RD, LODI 95240 <br /> Owner/Operator: LEE, H MAX Telephone: <br /> Program Element: 3611 -PUBLIC POOL/SPA-PRIMARY <br /> Inspection Type: ROUTINE INSPECTION -Operating Permit <br /> VIOLATIONS AND CORRECTIVE ACTIONS <br /> Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s)116043, 116040,& <br /> 116050. All violations must be corrected within specified timeframe. Violations that are classified as"MAJOR"pose an immediate threat to public health <br /> and must be corrected immediately or be subject to closure pursuant to California Code of Regulations(Title 22)section 65545. <br /> #1 Pool Gates MAJOR <br /> OBSERVATIONS:Observed pool gate unable to self-latch with rust observed around latch.All used gates leading to pool <br /> area must self-close and self-latch. Ensure proper gate functioning while in operation. Keep pool closed until correction is <br /> verified by EHD. <br /> CALCODE DESCRIPTION:Gates and doors leading into the pool area shall be equipped with self-closing self-latching devices. <br /> Self-latching devices shall be designed to keep the gate or door securely closed. Gates and doors shall open outward from the pool area <br /> except where otherwise prohibited by law. (CBC 31198) Pool operator shall keep gates and doors leading into the pool area well <br /> maintained. (CCR 65535) <br /> #37 Electrical Hazards MAJOR <br /> OBSERVATIONS:GFCI observed not functioning properly. Ensure properly properly functioning GFCI for light fixtures <br /> installed in the pool operating at more than 15 volts. Keep pool closed until correction is verified by EHD. <br /> CALCODE DESCRIPTION:Electrical equipment installed in the water, walls, deck, or equipment room of a public pool shall comply with <br /> California Electrical Code. (CEC 680.4)Light fixtures installed in the pool that operate at more than 15 volts shall be protected by a ground <br /> fault circuit interrupter. (CBC 31608) <br /> #9 Ladders and Handrails <br /> OBSERVATIONS:Observed one rail by steps at deep end of pool loose with loose chunks of concrete. Secure handrail <br /> within 2 weeks. <br /> CALCODE DESCRIPTION:A means of entry and exit shall be provided at both the shallow and deep end of the pool. Ladders and <br /> handrails shall be corrosion resistant and shall be rigidly installed.At least one handrail shall extend from the deck to not less than a point <br /> above the top of the lowest step.Handrails shall be installed between 28 to 36 inches above the steps and deck. (CBC 311 1B)Pool <br /> operator shall keep ladders and handrails well maintained. (CCR 65535) <br /> #22 Skimmer Assembly <br /> OBSERVATIONS:Observed no weir in one of the skimmers. Float valve assemblies are lacking for both skimmers. Provide <br /> missing skimmer assembly equipment. <br /> CALCODE DESCRIPTION:Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br /> maintained in accordance with manufacturer specifications. (CBC 31368) <br /> FA0000656 PR0360023 SCO01 08/01/2023 <br /> EHD 36-01 Rev.09/16/2020 Page 1 of 2 Swimming Pool OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.