My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0016022
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MANTHEY
>
9653
>
2600 - Land Use Program
>
PA-2300293
>
SU0016022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/23/2026 11:04:37 AM
Creation date
2/1/2024 7:38:29 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0016022
PE
2625 - CONDITIONAL USE MINOR (C)
STREET_NUMBER
9653
Direction
S
STREET_NAME
MANTHEY
STREET_TYPE
RD
APN
19323009
CURRENT_STATUS
Closed - Issued
QC Status
Approved
Scanner
SJGOV\gmartinez
Supplemental fields
Site Address
9653 S MANTHEY RD
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
COMMUNITY DEVELOPMENT DEPARTMENT <br /> SAN ,JOAQUIN ATIVEWCONDITIONAL USE PERMIT <br /> ADMINISTI� <br /> c� � �� i� �,_ <br /> ,r J`9.A � li ' <br /> SITE PLA H CHECKLIST con'dum c9 <br /> (Site plans must contain all applicable information contained in this checklist) <br /> ***Inc lete site ptans will not be accepted""* <br /> The following setbacks shall apply for private onsite wastewater treatment systems (septic tanks): <br /> o Private onsite wastewater treatment systems (septic tanks) <br /> 11 5 feet from all property lines, structures, driveways and swimming pools <br /> ® 100 feet from all domestic and irrigation wells, streams, waterways, drainage courses or ephemeral streams <br /> 150 feet from all public water wells <br /> Dispersal fields (leach lines) <br /> ® 10 feet from all structures, driveways and swimming pools <br /> 100 feet from all domestic and irrigation wells, streams, waterways, drainage courses or ephemeral streams <br /> 150 feet from all public water wells <br /> 200 feet from all public water wells if leach lines are greater than 8 feet in depth <br /> ® 600 feet from all public water wells if leach lines are greater than 20 feet in depth <br /> ® Identify and label future replacement areas for all septic systems (replacement area equals 100% of the OWTS area) <br /> ® All proposed replacement areas must meet all setback requirements listed in Table 1.5 of the San Joaquin County Onsite <br /> Wastewater Treatment Standards (OWTS) (This document can be viewed at+r,,!,,,�.,w.s c ov.crg/(Ieoartment/envhealih-E) <br /> WA❑ Identify and label all existing and proposed floor drains or other non-domestic wastewater collection systems <br /> Storm Drainage: (Contact the Department of Public Works at 209-468-3000 for questions regarding stormwater regulations) <br /> q/A❑ Identify and label existing and proposed storm drainage facilities <br /> TOPOGRAPHY: <br /> ® Identify any unusual topographic features of the site such as steep slopes and drainage courses <br /> NJAFI Identify topographic contours <br /> N/A❑ Identify any surface water (streams, ephemeral streams, irrigation canals, aqueducts, etc.) within 1 mile of all property <br /> boundaries (Note: If the surface water is not located adjacent to the subject property, a note on the site plan with approximate <br /> location is sufficient.) <br /> LEI- VADSCAPING: <br /> N/A❑ Identify and label existing and proposed landscaping. (See Chapter 9-1020 of the Development Title for <br /> Landscaping Regulations) <br /> M/A® Identify any trees proposed for removal <br /> SIGHS: <br /> N/A❑ Identify the location and dimensions of all existing and proposed signs including pole, monument, and attached signs. (See Chapters <br /> 9-1705 & 9-1710 for Sign Regulations) <br /> FENCING 8t SCREENING: <br /> N/A Identify the location and type of existing and proposed fencing and screening. (See Chapter 9-1022 of the <br /> Development Title for Fencing & Screening Regulations) <br /> MISCELLANEOUS: <br /> A Soil Suitability Study with Nitrate Loading Evaluation may be required prior to completion of the environmental review. <br />
The URL can be used to link to this page
Your browser does not support the video tag.