Laserfiche WebLink
S A N 10 A Q U I N Environmental Health Department <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> A G SPANOS AVIATION DEPT' 4800S AIRPORT WAY STOCKTON )ruary 06. 2024 <br /> Single-Walled Non-Pressurized Piping <br /> 404 CCR 2643(e),2661(f) Failure to conduct 0.1 gph test on single-walled gravity piping biennially or post repair(pre-1984) V R COS <br /> Other Violations <br /> 2010 See below Unlisted General violation ❑V _R _ COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> CCR 2636(f)(4) Failure to meet monitoring requirements in lieu of being tightness tested every 12 months. <br /> OBSERVATION:The three jet fuel tanks did not cause shutdown and do not meet the requirements for annual line <br /> tightness testing exemption during the inspection on 2/27/2023. <br /> REGULATION GUIDANCE:All pressurized piping with secondary containment shall be pressure tested at least <br /> once every 12 months at a minimum release detection of 0.1 gallons per hour at 150 percent of the normal <br /> operating pressure. Continuous monitoring systems that are fail safe and shut down the pump when a leak is <br /> detected, or optionally stop the flow of product at the dispenser if the leak is in the under dispenser containment <br /> (UDC), shall satisfy the requirement for annual line tightness testing. <br /> CORRECTIVE ACTION: Immediately schedule an annual line tightness test and provide 48 hours notification to the <br /> EHD. <br /> This is a Class II violation. <br /> 317 CCR 2636(f)(2) Failure of the line leak detector to detect a 3.0 gph leak at 10 psi and restrict or shut off flow. <br /> OBSERVATION: The jet fuel line leak detector for all three tanks were not tested during the time of inspection on <br /> 2/27/2023. <br /> REGULATION GUIDANCE:All line leak detectors shall be capable of detecting a 3-gallon per hour leak at 10 psi. <br /> CORRECTIVE ACTION: Immediately have a properly licensed,trained, and certified contractor repair or replace the <br /> failed leak detector(LG 113-x listed, if applicable)and obtain a permit within one business day from the EHD, if <br /> needed. If the failed leak detector can't be replaced immediately,there is a possibility that the jet fuel UST system <br /> may be red tagged to prevent fuel inputs. <br /> This is a Class II violation. <br /> 334 CCR 2670(b)(e)(f), 2671 Failure to comply with temporary closure requirements. <br /> OBSERVATION. Base on the report conducted on 2/27/2023, all three tanks were observed as empty.Temporary <br /> closure procedures were not followed. A.G. Spanos Jet Center, tank owner, states the UST system will be reused. <br /> REGULATION GUIDANCE: No person shall abandon or close or cease operating an UST system without <br /> complying with the requirements of HSC 25298. <br /> CORRECTIVE ACTION: Immediately obtain a permit from the EHD to temporarily close this UST system. A <br /> "Failure to Obtain a Permit"penalty applies. <br /> This is a Class I violation. <br /> FA0003809 PR0231509 SCO21 02/06/2024 <br /> EHD 23-01 Rev.12/06/2021 Page 4 of 5 Underground Storage Tank Program OR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />