My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2024
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
2358
>
2300 - Underground Storage Tank Program
>
PR0231756
>
COMPLIANCE INFO_2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2024 9:40:53 AM
Creation date
2/21/2024 2:00:03 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2024
RECORD_ID
PR0231756
PE
2361 - UST FACILITY
FACILITY_ID
FA0006343
FACILITY_NAME
SAI GAS AND FOOD
STREET_NUMBER
2358
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95205
APN
14118221
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
2358 E WATERLOO RD STOCKTON 95205
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
46
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br />Underground Storage Tank Program Inspection Report <br />Date: <br />April 12, 2024 <br /> Facility Address: <br /> 2358 E WATERLOO RD, STOCKTON <br /> Facility Name: <br /> SAI GAS AND FOOD <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br /> 301 HSC 25292.1(a) Failure to operate UST system to prevent unauthorized releases including leaks, spills and overfills. <br />OBSERVATION: The L2 diesel annular and L4 91 annular have had recurring sensor out alarms since 5/30/2023 <br />and 6/2/2023 respectively. The L4 sensor was found to still be in alarm at the time of inspection. Employee on site at <br />time of inspection stated Elite IV had previously been called to address alarms. No corresponding work orders or <br />documentation were observed on site. <br />REGULATION GUIDANCE: The underground storage tank system shall be operated to prevent unauthorized <br />releases, including spills and overfills. <br />CORRECTIVE ACTION: Service technician corrected alarms at the time of inspection, citing faulty wiring at the <br />panel. Confirm alarms are no longer occurring with supporting documentation or correct immediately by having a <br />properly licensed, trained, and certified contractor repair or replace the failed component with a functional <br />component (LG 113-x listed, if applicable), and obtain a permit within one business day from the EHD, if needed. <br />This is a Class II violation. <br /> 308 CCR 2632(c), 2634(d), 2636(f) Failure of the leak detection equipment to have an audible and visual alarm. <br />OBSERVATION: The float and chain in all UDCs failed to stop the flow of product at the dispenser when tested. <br />REGULATION GUIDANCE: All monitoring equipment shall be maintained to activate an audible and visual alarm or <br />stop the flow of product at the dispenser when it detects a leak. <br />CORRECTIVE ACTION: The service technician adjusted the float and chain and verified functionality. <br />This is a repeat violation, Class II. <br />Overall Inspection Comments: <br />An inspection checklist was provided to the facility operator on the day of inspection. A complete report was <br />finished on 4/29/2024 and replaces the initial checklist. <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />paperwork, within 30 days of receiving the complete inspection report, 5/29/2024 <br />AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING <br />THIS FACILITY BACK INTO COMPLIANCE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Received by: Inspector Phone: <br /> MATTHEW WON, EH Specialist <br /> Inspector:April 29, 2024 Date: <br />Printed Name and Title: <br />Emailed to Pardeep Kumar, Environmental Contact <br />(209) 616-3029 <br />FA0006343 PR0231756 SC001 04/12/2024 <br />EHD 23-01 Rev. 12/06/2021 Underground Storage Tank Program OIRPage 7 of 7 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD
The URL can be used to link to this page
Your browser does not support the video tag.