Laserfiche WebLink
i0 C', <br /> ai 0 SAN J O A Q U I N Environmental Health Department <br /> COUNTY Jasjit Kang , REHS , Director <br /> cgiP Greatness grows li e re . Muniappa Naidu, REHS , Assistant Director <br /> PROGRAM COORDINATORS <br /> Jeff Carruesco , REHS , RDI <br /> Willy Ng , REHS <br /> Steven Shih , REHS <br /> Elena Manzo , REHS <br /> Natalia Subbotnikova , REHS <br /> February 12 , 2024 <br /> Ramos Oil Company <br /> Ramos Oil Company <br /> PO BOX 401 <br /> W Sacramento , CA 95691 <br /> Iaurentramosoil . com <br /> Re : Ramos Oil Company SR0087697 <br /> 10842 S Harland Rd , French Camp , CA 95231 <br /> The San Joaquin County Environmental Health Department ( EHD ) has completed the review of the <br /> application for a 1 hour plan check service request to do the following on the underground storage tank <br /> ( UST) system at the above noted address : <br /> • Replace the penetration fitting on the satellite piping in under dispenser containment ( UDC) 1 . <br /> 2 , 2A- 3A , and 3-4 <br /> The plan check service request has been approved with the following conditions : <br /> 1 . Contact the local fire department and the San Joaquin Valley Air Pollution Control District for <br /> any applicable permits and requirements . <br /> 2 . Any changes in information and scope of work must be submitted to EHD for approval prior to <br /> commencing work . All new addenda supersede the previous ones . <br /> 3 . Provide written notification to ust( sictov . org to arrange the following repairs and testing (a 48- <br /> hour notice is required ) . <br /> a . A secondary containment test must be performed on the UDCs in accordance with the <br /> manufacturer' s guideline or equivalent and test results submitted to the EHD within 30 <br /> days of testing . <br /> b . Visual inspection of the piping and penetrations <br /> c . If concrete is broken near the piping and/or UDCs , a secondary containment test must <br /> be performed on the diesel tank once concrete is poured in accordance with the <br /> manufacturer' s guideline . <br /> 4 . Any individual performing the work of a service technician must meet the following <br /> qualifications : <br /> a . Possess or be employed by a person who possesses one of several permissible valid , <br /> current contractor' s licenses issued by the Contractors State License Board ( may be <br /> issued to the installation company) , or a Tank Tester' s license issued to the individual <br /> by the State Water Board <br /> b . Possess or work under the direct and personal supervision of an individual physically <br /> present at the work site who possesses a valid , current California UST Service <br /> Technician certificate issued by the International Code Council ( ICC ) <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www . sjgov . org/ehd <br />