My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2024
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
3940
>
2800 - Aboveground Petroleum Storage Program
>
PR0536557
>
COMPLIANCE INFO_2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/28/2024 1:48:42 PM
Creation date
2/28/2024 1:38:36 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2024
RECORD_ID
PR0536557
PE
2832
FACILITY_ID
FA0008057
FACILITY_NAME
H&S ENERGY PRODUCTS, LLC 3084
STREET_NUMBER
3940
Direction
N
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95304
APN
21220004
CURRENT_STATUS
01
SITE_LOCATION
3940 N TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br />AMENDED <br />2/2/2024 <br />Aboveground Petroleum Storage Act Inspection Report <br />Date: <br />January 18, 2024 <br /> Facility Address: <br /> 3940 N TRACY BLVD, TRACY <br /> Facility Name: <br /> H&S ENERGY PRODUCTS, LLC 3084 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br /> 610 CFR 112.7(a)(3vi), 112.7(a4) Plan failed to adequately detail information and procedures for reporting a discharge. <br />OBSERVATION: The Spill Prevention, Control, and Countermeasure (SPCC) Plan does not adequately discuss <br />procedures for reporting a discharge. The plan references Appendix H and is titled Agency Notification List. The <br />notification list had the incorrect phone number listed for the San Joaquin County Environmental Health Department. <br />The number listed was (209) 468-4400 and the correct number is (209) 468-3420. <br />REGULATION GUIDANCE: The SPCC plan shall include: (vi) Contact list and phone numbers for the facility <br />response coordinator, National Response Center, cleanup contractors with whom you have an agreement for <br />response, and all appropriate Federal, State, and local agencies who must be contacted in case of a discharge as <br />described in § 112.1(b). <br />(4) Unless you have submitted a response plan under § 112.20, provide information and procedures in your Plan to <br />enable a person reporting a discharge as described in § 112.1(b) to relate information on the exact address or <br />location and phone number of the facility; the date and time of the discharge, the type of material discharged; <br />estimates of the total quantity discharged; estimates of the quantity discharged as described in § 112.1(b); the <br />source of the discharge; a description of all affected media; the cause of the discharge; any damages or injuries <br />caused by the discharge; actions being used to stop, remove, and mitigate the effects of the discharge; whether an <br />evacuation may be needed; and, the names of individuals and/or organizations who have also been contacted. <br /> <br />CORRECTIVE ACTION: The phone number was corrected during the inspection. The violation was corrected on <br />site. <br />This is a Class II violation. <br /> 612 CFR 112.7(b) Plan doesn't have discharge prediction, including direction, rate of flow, and quantity of oil. <br />OBSERVATION: The Spill Prevention, Control, and Countermeasure (SPCC) Plan failed to predict the direction, <br />rate of flow, and the total quantity of the oil that could be discharged for each type of major equipment failure. The <br />potential equipment failure and the resulting spill from the 55 gallon drums stored on site were not adequately <br />addressed in the SPCC Plan. Inconsistencies were noted in the plan. Per Table G-3, direction of flow states that a <br />release will pool. Per Table 3-1 direction of flow for the drums is listed as "N/A." <br />REGULATION GUIDANCE: (b) Where experience indicates a reasonable potential for equipment failure (such as <br />loading or unloading equipment, tank overflow, rupture, or leakage, or any other equipment known to be a source of <br />a discharge), include in your Plan a prediction of the direction, rate of flow, and total quantity of oil which could be <br />discharged from the facility as a result of each type of major equipment failure. <br />CORRECTIVE ACTION: SPCC Plan shall be updated so that portions describing procedures to be used when a <br />discharge occurs (for each type of major equipment failure, specifically the 55 gallon drums) will be readily usable in <br />an emergency. Submit proof of correction of the inconsistencies to the EHD. <br />This is a Class II violation. <br />FA0008057 PR0536557 SC001 01/18/2024 <br />EHD 28-01 Rev. 12/06/2021 Aboveground Petroleum Storage Act OIRPage 6 of 9 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD
The URL can be used to link to this page
Your browser does not support the video tag.