My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2024
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
4315
>
2300 - Underground Storage Tank Program
>
PR0231760
>
COMPLIANCE INFO_2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/25/2024 3:58:52 PM
Creation date
3/11/2024 8:14:33 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2024
RECORD_ID
PR0231760
PE
2351
FACILITY_ID
FA0003831
FACILITY_NAME
WATERLOO FOODMART
STREET_NUMBER
4315
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95215
APN
08710034
CURRENT_STATUS
01
SITE_LOCATION
4315 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN J 0 A Q I I I Irl Environmental Health Department <br /> CCUN r <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> WATERLOO FOODMART 4315 E WATERLOO RD, STOCKTON March 19, 2024 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 208 CCR 2716(a-e) Failure to comply with the designated operator inspection requirements. <br /> OBSERVATION: The designated operator failed to check and note all required items on the visual inspection <br /> reports.The incorrect and missing information included the following from the inspection reports: <br /> -S alarms were not printed on all the attached alarm histories, including the 6/28/23 report <br /> -The designated operator marked that sumps were inspected, but did not indicate whether sensors were in the <br /> proper location. <br /> REGULATION GUIDANCE: During the visual inspection,the designated operator shall check that all required <br /> testing and maintenance for the UST system have been completed and shall check all required items on the report. <br /> CORRECTIVE ACTION: Ensure that designated operators performing visual inspections at this facility are including <br /> all of the required information on the reports. <br /> OBSERVATION: The designated operator failed to document all the alarms from the attached alarm history on the <br /> designated operator inspection reports and failed to check that they were responded to appropriately. The missing <br /> and incorrectly listed alarms include: <br /> -The designated operator stated the L9(UDC 5/6)fuel and sensor out alarms on 12/8/23"cleared by itself'. <br /> According to an email sent to EHD by Elite IV,the alarms were caused by a sensor replacement. <br /> -The designated operator listed alarms on Q3.According to the panel setup, there is no Q3. <br /> -Q1 (87)gross line fail on 12/8/23 <br /> -Q1 (87)gross line fail on 11/24/23 <br /> -Q2(91)gross line fail on 9/27/23 <br /> -Q2(91)gross line fail on 10/17/23 <br /> -Q2(91)gross line fail on 11/16/23 <br /> -S3(91 line)setup data warning on 11/16/23 <br /> -S3(91 line)no vacuum alarm on 11/6/23 <br /> -S4(vents 91 STP)no vacuum alarm on 7/11/23 <br /> -S4(vents 91 STP)no vacuum alarm on 11/6/23 <br /> -S4(vents 91 STP)setup data warning on 11/16/23 <br /> REGULATION GUIDANCE: During the inspection,the designated operator shall review the alarm history since the <br /> previous inspection, check that each alarm was documented and responded to appropriately, and attach a copy of <br /> the alarm history with documentation taken in response to any alarms to the inspection report. <br /> CORRECTIVE ACTION: Ensure that designated operators performing inspections at this facility are including all of <br /> the required information on the reports. <br /> This is a repeat violation, Class II. <br /> FA0003831 PR0231760 SCO01 03/19/2024 <br /> EHD 23-01 Rev.12/06/2021 Page 5 of 7 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.