A NJ O A Q U l N Environmental Health Department <br /> COUNTY— <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> SUSD-CORPORATE YARD 1932 EL PINAL DR, STOCKTON May 02, 2024 <br /> Single-Walled Non-Pressurized Piping <br /> 404 CCR 2643(e),2661(f) Failure to conduct 0.1 gph test on single-walled gravity piping biennially or post repair(pre-1984) ❑V ❑R ❑COS <br /> Other Violations <br /> 2010 See below Unlisted General violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 104 CCR 2632(d)(1), 2634(d)Failure to submit a complete and accurate UST Monitoring Plan. <br /> OBSERVATION: The monitoring plan is not current and/or not approved by the EHD. <br /> -The monitoring panel listed for the 87 tank is Incon TS-1000 2-P but was observed on site at Incon TS-550 EVO <br /> -The UDC sensor listed for the diesel tank is Incon ELS but was observed on site to be Incon ULS. <br /> REGULATION GUIDANCE: The monitoring plan must be uploaded to the California Environmental Reporting <br /> System (CERS). <br /> CORRECTIVE ACTION: Immediately log into CERS, make the necessary changes, and submit for review by the <br /> EHD. <br /> This is a repeat violation, Class II. <br /> 107 HSC 25292.2; CCR 2711(a)(11)Failure to submit and maintain complete and current financial responsibility <br /> documents. <br /> OBSERVATION: Financial responsibility documents have not been submitted to the EHD. The financial <br /> responsibility mechanism listed in CERS is self insurance, but the uploaded document is Letter from Chief Financial <br /> Officer Letter to be used in conjunction with the UST Clean Up Fund and not a test for self insurance. <br /> REGULATION GUIDANCE: CFR 280.95 (a)An owner or operator, and/or guarantor, may satisfy the requirements <br /> of§280.93 by passing a financial test as specified in this section. To pass the financial test of self-insurance, the <br /> owner or operator, and/or guarantor must meet the criteria of paragraph (b)or(c)of this section based on year-end <br /> financial statements for the latest completed fiscal year. <br /> CORRECTIVE ACTION: Immediately log into the California Environmental Reporting System (CERS)at <br /> http://cers.calepa.ca.gov/, and upload the required documents. See CFR 280.95 (d)for letter to be used. <br /> This is a repeat violation, Class II. <br /> FA0004016 PR0231097 SCO01 05/02/2024 <br /> EHD 23-01 Rev.12/06/2021 Page 4 of 6 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />