My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WP0044048
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
J
>
JAHANT
>
5790
>
4200/4300 - Liquid Waste/Water Well Permits
>
WP0044048
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/11/2024 8:21:11 AM
Creation date
3/20/2024 2:29:28 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4200/4300 - Liquid Waste/Water Well Permits
RECORD_ID
WP0044048
PE
4380
STREET_NUMBER
5790
Direction
E
STREET_NAME
JAHANT
STREET_TYPE
RD
City
GALT
Zip
95632-
APN
00518016
ENTERED_DATE
11/14/2022 12:00:00 AM
SITE_LOCATION
5790 E JAHANT RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\gmartinez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 <br /> nU" SAN JOAQUIN Environmental Health Department <br /> COUNTY Jasjit Kang, RENS, Director <br /> 0,OF0 P Greatness grows here. Muniappa Naidu, REHS,Assistant Director <br /> PROGRAM COORDINATORS <br /> Jeff Carruesco, REHS, RDI <br /> Willy Ng, REHS <br /> Steven Shih, REHS <br /> Elena Manzo, REHS <br /> Natalia Subbotnikova, REHS <br /> January 16, 2024 <br /> Issac and Angelica Adame <br /> 5790 E. Jahant Rd <br /> Galt, CA 95632 <br /> RE: Well Pump Inspection <br /> Well Location: 5790 E.Jahant Rd, Galt Permit#: WP0044048 Inspection Date: 1-16-2024 <br /> The Environmental Health Department recently conducted a water well pump inspection at the above address <br /> and found the following issues at the time of the inspection. In order to protect the ground water supply and <br /> your water source from potential degradation, please take the associated corrective actions. <br /> ❑ Lack of or Inadequate Concrete Platform around Wellhead. <br /> (SJC Water Well Standards, Section 4.10.—Surface Seal) <br /> Corrective Action: Repair existing or install a new concrete platform around the wellhead that <br /> extends two feet in all directions from the well casing. <br /> © Lack of or Inadequate Sanitary Seal at Wellhead. <br /> (SJC Ord. Code,Title 9, Section 9-1115.5.—Well Regulations) <br /> Corrective Action: Chlorination port cap missing. Install cap immediately to seal off potential <br /> contamination conduct. <br /> ❑ Lack of or Inadequate Sampling Tap. <br /> (SJC Water well Standards, Section 4.13.—Sampling Tap) <br /> Corrective Action: Install a non-threaded sampling tap between the wellhead and the check valve <br /> or within three (3) feet of the well head. <br /> ❑ Lack of or Inadequate Backflow Prevention. <br /> (SJC Water Well Standards, Section 4.14.—Backflow Prevention) <br /> Corrective Action: Install an approved protective device to prevent backflow and/or back <br /> siphonage into a well. <br /> ❑ Sounding Tube or Air Vent not Sealed. <br /> (SJC Water Well Standards, Section 4.13.—Sounding Tube/Air Vent Pipe) <br /> Corrective Action: Sounding Tube or Fill Pipe-Install a watertight, threaded cap at the upper end <br /> of the pipe. Air Vent-extend pipe 12 inches above with end inverted in a <br /> downward direction and covered with 16-mesh screening. <br /> ❑ Excessive Vegetation or debris around Wellhead. <br /> (SJC Ord. Code, Section 9-1115.4.—Dangerous/Nuisance) <br /> Corrective Action: Remove and maintain debris and vegetation away from well area. <br /> If you have any questions, contact Naseem Ahmed, Senior Registered Environmental Health Specialist. <br /> Email: nahmed@sjgov.org <br /> Please call — (209) 616-3018 when work is complete. <br /> AA <br /> �vt <br /> /Steven Shih, REHS <br /> - Program Coordinator <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.