My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2024
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1257
>
2300 - Underground Storage Tank Program
>
PR0231463
>
COMPLIANCE INFO_2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/25/2024 9:54:49 AM
Creation date
3/26/2024 8:47:25 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2024
RECORD_ID
PR0231463
PE
2361
FACILITY_ID
FA0003707
FACILITY_NAME
AHMEDS SONS INC
STREET_NUMBER
1257
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
20015015
CURRENT_STATUS
01
SITE_LOCATION
1257 W YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
85
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SANAMU <br /> Environmental Health Department <br /> IIY <br /> - COUNTY <br /> ` � f Greatness grows here, <br /> CP22 - UST FULL Compliance Review Report <br /> Facility Name: Facility Phone: Date: <br /> AHMEDS SONS INC 209 823-1724 July 03 2024 <br /> Facility Address: CERS ID: <br /> 1257 W YOSEMITE AVE MANTECA CA 95336 10181329 <br /> Inspection Contact: Title: Phone: <br /> Asim Ahmed Environmental Contact (209)823-1724 <br /> VIOLATIONS <br /> The following non-inspection related violations listed below from the California Health and Safety Code(HSC), California Code of <br /> Requlations(CCR)and/or the Code of Federal Regulations(CFR)were found. <br /> #9 CA Code of Regulations 2638,26416), 2715(f) 2030002-Leak detection equipment tested by qualified service <br /> technician every 12 months (TCR 9d) <br /> OBSERVATIONS:OBSERVATION:The annual monitoring system certification and leak detector testing were last performed on <br /> 4/11/2023 and were due by May 2024. Testing has not been completed for the 87, 91, and Diesel annular sensors and is 3 <br /> months past due. <br /> REGULATION GUIDANCE:These tests are required once every 12 months. <br /> CORRECTIVE ACTION: Immediately schedule these tests and provide 48 hours notification to the EHD. Please be aware that <br /> all EHD staff time associated with a follow up inspection will be billed at our current hourly rate ($156). <br /> This is Repeated (Class 2) Violation. <br /> #11 CA Code of Regulations 2637(a-d),2712(b)(1)(F) 2030048-Sec containment testing conducted per requirements& <br /> records kept for 36 mths(TCR 9d) <br /> OBSERVATIONS:OBSERVATION: Secondary containment testing was last performed on 5/11/2021 and was due by May <br /> 2024. Testing has not been completed and is over 1 month past due. <br /> REGULATION GUIDANCE: Secondary containment testing is required to be performed once every 36 months. <br /> CORRECTIVE ACTION: Immediately schedule this test and provide 48 hours notification to the EHD. <br /> This is Repeated (Class 2)Violation. <br /> PR0231463 SC1822 07/03/2024 <br /> Rev.9/16/2020 Page 1 of 2 CP22-UST FULL Compliance Review Report <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.