Mr. Joyesh Chandra <br />October 13, 2023 <br />Page 2 <br /> <br />• For probes more than 20 feet deep, turn on sample pump, extract a minimum of one <br />probe volume, observed and record methane, oxygen, and carbon dioxide gas <br />concentrations, when readings have stabilized for 30 seconds. <br />• Close test valve, disconnect sample instruments and secure sample location. <br /> <br />SCS monitored structure vent risers as directed by the County. Other required monitoring <br />documentation (e.g., sampling personnel, date, time and meteorological conditions) is shown on the <br />attached testing data tables. Instrument calibration logs are attached to this report. <br />GAS MONITORING WELL TESTING <br />In accordance with the approved testing schedule, all perimeter GW probes are to be tested at a <br />minimum, on a quarterly basis. On August 24, 2023, all compliance perimeter monitoring probes <br />defined as GW Nos. 1 through 12 were tested. Results of GW probe testing (Table 1) indicated that all <br />GW probes exhibited methane gas concentrations below the LEL (5 percent by volume) or no methane <br />gas was detected. SCS will continue to monitor all probes quarterly as directed by the County. SCS is <br />scheduled to perform the fourth quarter monitoring 2023 (October through December) of all the GW <br />probes before the end of the month of December 2023. <br />STRUCTURE VENT RISER TESTING <br />In accordance with the approved testing schedule, the structure vent risers are to be tested on a <br />quarterly basis. On August 30, 2023, all vent risers were tested for the presence of methane gas. <br />Test results (Table 2) indicated no methane gas was detected at any structure vent riser location <br />tested. SCS is scheduled to perform the fourth quarter monitoring 2023 (October through December) <br />of the structure vent risers before the end of the month of December 2023. <br />STANDARD PROVISIONS <br />This report addresses conditions at the subject site during the test date only. Accordingly, we <br />assume no responsibility for any changes that may occur subsequent to our monitoring which could <br />affect the quantity of LFG at the subject site or adjacent properties. <br /> <br />Should you have any questions, do not hesitate to contact Justin Ruhle at (209) 279-4418. <br /> <br />Sincerely, <br /> <br /> <br /> <br /> <br /> <br />Rebecca L. Lucero Justin C. Ruhle <br />Project Coordinator Project Manager <br />SCS Field Services SCS Field Services <br />