My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2024
>
EHD Program Facility Records by Street Name
>
D
>
DANIELS
>
1904
>
2300 - Underground Storage Tank Program
>
PR0541937
>
COMPLIANCE INFO_2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/11/2024 8:40:55 AM
Creation date
3/28/2024 9:00:48 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2024
RECORD_ID
PR0541937
PE
2351
FACILITY_ID
FA0024059
FACILITY_NAME
ARCO AM/PM #83831*
STREET_NUMBER
1904
STREET_NAME
DANIELS
STREET_TYPE
ST
City
MANTECA
Zip
95337
CURRENT_STATUS
01
SITE_LOCATION
1904 DANIELS ST
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank <br /> Monitoring System Certification Form <br /> 8. IN-TANKGAUGIISG TESTING <br /> XCheck this box if tan gauging is used only for inventory control. <br /> ❑Check this box if No tank gauging equipment is installed. Yes No NA <br /> Do not complete t Ws section if either box is checked. <br /> All wiring has been: 1 visually inspected for kinks, breaks and proper entry and termination; ❑ ❑ ❑ <br /> and 2 tested for grouid faults? <br /> Were all in-tank gauging probes visually inspected for damage and residue buildup to ❑ ❑ <br /> ensure that floats move freely, functionally tested, and confirmed operational? <br /> Was accuracy of system's product level readings tested? ❑ ❑ ❑ <br /> Was accuracy of system's water level readings tested? ❑ ❑ ❑ <br /> Were all probes reinstalled properly? ❑ ❑ ❑ <br /> Were all items on the equipment manufacturer's maintenance checklist completed? ❑ 1 ❑ ❑ <br /> Probe ID P obe Model Tanks Monitored Pass Fail <br /> O ❑ <br /> O ❑ <br /> O ❑ <br /> 9. COMMENTS <br /> Describe all answers marked "No"or"Fail"and proposed remedy. <br /> List all monitoring eqi tioment either replaced or repaired. <br /> 1) 1_2: 87 Fill Sump Sensor model 794380-304 and the Veeder Root 2 to 1 Sensor Input Box# 332504-001 <br /> were replaced "like f r like" due to failure after completion of the monitoring certification <br /> 10. MONITORING SITE PLAN <br /> Page 5 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.