My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2024
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DANIELS
>
1904
>
2300 - Underground Storage Tank Program
>
PR0541937
>
COMPLIANCE INFO_2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/23/2026 8:25:37 PM
Creation date
3/28/2024 9:00:48 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2024
RECORD_ID
PR0541937
PE
2351 - UST FACILITY - 2481 COMPLIANT
FACILITY_ID
FA0024059
FACILITY_NAME
ARCO AM/PM #83831*
STREET_NUMBER
1904
STREET_NAME
DANIELS
STREET_TYPE
ST
City
Manteca
Zip
95337
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
1904 DANIELS ST MANTECA 95337
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
47
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank <br /> verrill Prevention Equipment Inspection Report <br /> 6. OVERFILL PREVENTION EQUIPMENT DETAILS <br /> Tank ID (one OPE per column) T1: 87 N T1: 87 S T2: 91 T3: Diesel <br /> Are both vent and tank riser piping N Yes N Yes N Yes E Yes <br /> secondarily contai ied? ❑ No ❑ No ❑ No ❑ No <br /> OPE Model OPW71 SO OPW71 SO OPW71 SO OPW71 SO <br /> What is the OPE r sponse when activated? N Shut off E Shut off N Shut off E Shut off <br /> (Check all that apply.) Flow Flow Flow Flow <br /> ❑Restricts ❑Restricts ❑Restricts ❑Restricts <br /> Flow Flow Flow Flow <br /> ❑ Audible O Audible ❑ Audible ❑ Audible <br /> Alarm Alarm Alarm Alarm <br /> ❑ Visual ❑ Visual ❑ Visual ❑ Visual <br /> Alarm Alarm Alarm Alarm <br /> Are flow restrictorE installed on vent piping ❑ Yes* ❑ Yes* ❑ Yes* ❑ Yes* <br /> that may interfere with the OPE operation? N No E No E No E No <br /> At what level in the tank is the OPE set to 103 1/2" 102 3/4" 105 1/4" 106 1/4" <br /> activate? Inches from bottom of tank <br /> What is the percer t capacity of the tank at 93.08 92.56 94.63 94.60 <br /> which the OPE ac ivates? <br /> Is the OPE in prop ar operating condition to N Yes E Yes E Yes E Yes <br /> respond when the 3tored substance ❑ No ❑ No ❑ No ❑ No <br /> reaches the desigr ated regulatory level? <br /> 7. SUMMARY OF TESTING RESULTS <br /> OPE Inspection Results E Pass E Pass N Pass N Pass <br /> ❑ Fail ❑ Fail ❑ Fail ❑ Fail <br /> 8. COMMENTS <br /> Describe all result marked "Fail'and each proposed remedy. <br /> * Mark here if: <br /> ❑ Flow restrictors nterfere with overfill prevention and equipment repairs required. <br /> Additional copies of this page may be attached. <br /> Attach tank charts) measurements, calculations, and In-Tank Setup report(s) <br /> Page 2 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.