Laserfiche WebLink
A dOAQU1N Environmental Health Department <br /> CQLJIVTY AMENDED <br /> 6/18/2024 <br /> CP22 - UST FULL Inspection Report <br /> Facility Name: Facility Address: Date: <br /> HUNT&SONS INC-STOCKTON 4733 S HWY 99 STOCKTON June 06 2024 <br /> 86 CA Code of Regulations 2060024-UST system is made of or lined with materials that are compatible with the substance ❑OUT ❑R ❑COS <br /> 2631.1,2660(m) stored. <br /> 87 CA Code of Regulations 2060021-Striker plate installed and positioned correctly. ❑OUT ❑R ❑COS <br /> 2631(c),2662(d) <br /> 88 CA Code of Regulations 2060007-Primary and secondary containment designed and constructed to an engineering ❑OUT ❑R ❑COS <br /> 2631(b&d),2666(b&e) specification. <br /> 89 CA Health and Safety 2060008-Enhanced leak detection testing performed before the tank is placed in use ❑OUT ❑R ❑COS <br /> Code 25290.10) <br /> 90 CA Code of Regulations 2060029-SW piping has been upgraded to continuously monitored DW piping when replacement ❑OUT ❑R ❑COS <br /> 2666(b)(2) or repair needed <br /> 91 CA Health and Safety 2010-Administration/Documentation-General ❑OUT ❑R ❑COS <br /> Code 25291(e) <br /> 92 2015-Administrative/Documentation-General Local Ordinance ❑OUT ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 7 CA Code of Regulations 2715(a)(1)(B), 2715(a)(3)2010003-Owner/Operator submitted DO form and/or informed the <br /> CUPA of any change(s)within 30 days(TCR 10). <br /> OBSERVATION:A new designated operator, Genardo Perez, began conducting inspections on 9/8/2023 and <br /> notification was not provided to the EHD within 30 days of the change. <br /> REGULATION GUIDANCE:The owner or operator shall submit a"Designated Underground Storage Tank Operator <br /> Identification Form" no later than 30 days after any change in the designated UST operator(s). <br /> CORRECTIVE ACTION: Immediately log into the California Environmental Reporting System (CERS)at <br /> http://cers.calepa.ca.gov and upload the notification identifying all the designated operators for this facility. <br /> This is a repeat violation (Class 2) Violation. <br /> 56 CA Code of Regulations 2716(a-e)2030013-DO inspections completed at least every 30 days and meet all <br /> requirements(TCR 12). <br /> OBSERVATION:The designated operator failed to check and note all required items on the visual inspection reports. <br /> The incorrect and missing information included the following from the inspection reports: <br /> -6/21/2023 section#6 did not include a printed name <br /> -9/8/2023 DO report is missing section#6 signature, missing CERS ID, and date <br /> -All the DO reports contained the wrong Secondary Containment date of 12/29/2021. <br /> REGULATION GUIDANCE: During the visual inspection,the designated operator shall check that all required testing <br /> and maintenance for the UST system have been completed and shall check all required items on the report. <br /> CORRECTIVE ACTION: Ensure that designated operators performing visual inspections at this facility are including all <br /> of the required information on the reports. <br /> This is a repeat violation (Class 2) Violation. <br /> 59 CA Code of Regulations 2712(b)(1-2)2030001 - Records of release detection monitoring and maintenance properly <br /> maintained (TCR 9d). <br /> OBSERVATION: Maintenance and monitoring records for the last three years were not found on site. 10/9/2023 work <br /> order, 5/4/2023 Monitoring system certification for cold start <br /> FA0003924 PR0232510 SCO01 06/06/2024 <br /> EHD Rev.12/06/2021 Page 5 of 7 CP22-UST FULL OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />