COMPLIANCE INFO_2024
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CENTER
>
430
>
2300 - Underground Storage Tank Program
>
PR0231425
>
COMPLIANCE INFO_2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/1/2026 8:07:17 PM
Creation date
4/16/2024 8:20:56 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2024
RECORD_ID
PR0231425
PE
2361 - UST FACILITY
FACILITY_ID
FA0003838
FACILITY_NAME
FRONTIER CALIFORNIA INC. MANTECA CO
STREET_NUMBER
430
Direction
W
STREET_NAME
CENTER
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
21721070
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
430 W CENTER ST MANTECA 95336
标签
EHD - Public
该页面上没有批注。
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
191
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank <br />Monitoring System Certification Form <br />8. IN -TANK GAUGING TESTING <br />❑ Check this box if tank gauging is used only for inventory control. <br />❑ Check this box if NO tank gauging equipment is installed. <br />(Do not complete this section if either box is checked.) <br />Yes <br />No <br />NA <br />All wiring has been: 1) visually inspected for kinks, breaks and proper entry and <br />termination; and 2) tested for ground faults? <br />® <br />❑ <br />❑ <br />Were all in -tank gauging probes visually inspected for damage and residue buildup <br />to ensure that floats move freely, functionally tested, and confirmed operational? <br />® <br />❑ <br />❑ <br />Was accuracy of system's product level readings tested? <br />® <br />❑ <br />❑ <br />Was accuracy of system's water level readings tested? <br />® <br />1 ❑ <br />❑ <br />Were all probes reinstalled properly? <br />® <br />❑ <br />❑ <br />Were all items on the equipment manufacturer's maintenance checklist <br />cnm nlPtpd? <br />® <br />❑ <br />❑ <br />Probe ID <br />Probe Model <br />Tanks Monitored <br />Pass Fail <br />T-1/ Diesel <br />Veeder Root <br />T-1/ Diesel <br />z❑ <br />❑ ❑ <br />❑ ❑ <br />❑ ❑ <br />❑ ❑ <br />❑ ❑ <br />9. COMMENTS <br />Describe all answers marked "No" or "Fail" and proposed remedy. <br />List all monitoring equipment either replaced or repaired. <br />Replaced sump sensors, transition sump sensors, and annular Space sensor, and replaced the <br />sensor module in the veeder root, performed a cold start reprogrammed the monitoring panel and <br />tested all sensors and tank gauge and they all tested good <br />Page 5 of 15 <br />