My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2024
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CENTER
>
430
>
2300 - Underground Storage Tank Program
>
PR0231425
>
COMPLIANCE INFO_2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/1/2026 8:07:17 PM
Creation date
4/16/2024 8:20:56 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2024
RECORD_ID
PR0231425
PE
2361 - UST FACILITY
FACILITY_ID
FA0003838
FACILITY_NAME
FRONTIER CALIFORNIA INC. MANTECA CO
STREET_NUMBER
430
Direction
W
STREET_NAME
CENTER
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
21721070
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
430 W CENTER ST MANTECA 95336
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
191
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
nteg rated solution for centra ize , <br />single system site monitoring. <br />Standard Models <br />Five -Input Groundwater Sensor Module <br />Console Form Number: <br />848290-022 <br />Description: <br />TLS -350 Plus monitoring console with integral printer <br />Console Form Number: <br />848290-002 <br />Description: <br />TLS -350 Plus monitoring console without integral printer <br />Console Form Number: <br />848291-021 <br />Description: <br />TLS -350 Plus PC version without printer, keyboard or display <br />TLS -350 Plus Interface Modules <br />The TLS -350 Plus monitoring console contains three compartments in which individual interface modules can be installed. Interface modules <br />may be factory -installed in the console upon initial ordering, or ordered separately as spare modules to expand an existing system. <br />Form No. <br />Factory <br />Installed <br />Modules Description Feature Compatibility (where applicable) <br />LOW-POWER COMPARTMENT (Limit eight per console, unless otherwise noted) <br />329356-002 Four -Input Probe Interface Module (Maximum three per Series 8473 0.1 GPH Magnetostrictive Probe <br />console. Includes terminal connector for one ground <br />329399-001 <br />Five -Input Groundwater Sensor Module <br />4SITE Series 7943 Groundwater Sensor <br />329956-001 <br />Eight -Input Type A Sensor Interface Module <br />4SITE Series 7943 Discriminating Interstitial Sensor <br />329950-001 <br />Six -Input Type B Sensor Interface Module <br />4SITE Series 7943 Discriminating Dispenser <br />330843-001 <br />Six -Input Pressurized Line Leak Interface <br />Module (One per console) <br />Series 8484 Pressurized Line Leak Detection System <br />Requires TLS -350 Plus version 7.0 or higher software <br />HIGH-POWER COMPARTMENT (Limit eight per console, unless otherwise noted) <br />329359-001 <br />Four -Relay Output Interface Module <br />329360-001 <br />Two-Input/Two-Relay Output Interface Module <br />329999-001 <br />Pump Sense Interface Module <br />Accepts up to four inputs. <br />330374-001 <br />Three -Output Pressurized Line Leak <br />Series 8484 Pressurized Line Leak Detection System <br />Controller Interface Module (Two per console) <br />Requires TLS -350 Plus version 7.0 or higher software <br />COMMUNICATIONS COMPARTMENT (Limit three per console, unless otherwise noted) <br />330149-002 <br />SiteFax Interface Module <br />Allows hookup to most remote facsimile, modem or teletype <br />equipment. Requires TLS -350 Plus version 3.0 or higher software. <br />330586-001 <br />RS -485/232 Dual Port Communications Module (Slot 4 only) <br />330148-001 <br />RS -232 Interface Module with Auxiliary Port <br />Provides two 25 -pin D -connectors for data transmission to <br />P.O.S. terminal, printing device or computer <br />329362-001 <br />RS -232 Interface Module <br />Provides a 25 -pin D -connector for data transmission to <br />P.O.S. terminal, printing device, or computer <br />330000-001 <br />Remote Printer Interface Module <br />Provides a 25 -pin D -connector for data transmission <br />to a remote serial printer <br />330883-001 <br />WPLLD Communications Module <br />(Maximum one per console) <br />330020-425 Ethernet—TCP/IP Communications module <br />Specifications <br />Operating Temperature Range 32°F to 118°F (0°C to 45°C) <br />Storage Temperature Range 15°F to 118°F (10°C to 45°C) <br />Provides connectivity to local and wide area networks (LAN/WANS) <br />For more information call <br />1-888-561-7942 <br />VEEDER-ROOT © 2003 Veeder-Root Company - 125 Powder Forest Drive - Simsbury, CT 06070 - USA <br />Telephone: 860-651-2700 - Fax : 860-651-2719 - www.veeder.com <br />VR 13679 P/N 0576047-022 Rev.D VRLP 8/2003 Printed in USA <br />