COMPLIANCE INFO_2024
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CENTER
>
430
>
2300 - Underground Storage Tank Program
>
PR0231425
>
COMPLIANCE INFO_2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/1/2026 8:07:17 PM
Creation date
4/16/2024 8:20:56 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2024
RECORD_ID
PR0231425
PE
2361 - UST FACILITY
FACILITY_ID
FA0003838
FACILITY_NAME
FRONTIER CALIFORNIA INC. MANTECA CO
STREET_NUMBER
430
Direction
W
STREET_NAME
CENTER
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
21721070
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
430 W CENTER ST MANTECA 95336
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
191
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Appendix IX <br />Underground Storage Tank <br />Overfill Prevention Equipment Inspection Report Form <br />CERS = California Environmental Reporting System, ID = Identification, ICC = International Code <br />Council, OPE = Overfill Prevention Equipment <br />Page 2 of 8 <br />6. OVERFILL PREVENTION EQUIPMENT DETAILS <br />Tank ID (one OPE per column) T-1/ Diesel <br />Are both vent and tank riser piping <br />secondarily contained? <br />Yes <br />No <br />Yes <br />No <br />Yes <br />No <br />Yes <br />No <br />OPE Model Veeder <br />What is the OPE response when activated? <br />(Check all that apply.) <br />Shuts off <br /> Flow <br />Restricts <br /> Flow <br />Audible <br /> Alarm <br />Visual <br /> Alarm <br /> <br />Shuts off <br /> Flow <br />Restricts <br /> Flow <br />Audible <br /> Alarm <br />Visual <br /> Alarm <br /> <br />Shuts off <br /> Flow <br />Restricts <br /> Flow <br />Audible <br /> Alarm <br />Visual <br /> Alarm <br /> <br />Shuts off <br /> Flow <br />Restricts <br /> Flow <br />Audible <br /> Alarm <br />Visual <br /> Alarm <br /> <br />Are flow restrictors installed on vent piping <br />that may interfere with the OPE operation? <br />Yes <br />No <br />Yes <br />No <br />Yes <br />No <br />Yes <br />No <br />At what level in the tank is the OPE set to <br />activate? (Inches from bottom of tank) <br />77.5 <br />What is the percent capacity of the tank at <br />which the OPE activates? <br />90 <br />Is the OPE in proper operating condition to <br />respond when the stored substance reaches <br />the designated regulatory level? <br />Yes <br />No <br />Yes <br />No <br />Yes <br />No <br />Yes <br />No <br />7. SUMMARY OF TESTING RESULTS <br />OPE Inspection Results Pass <br />Fail <br />Pass <br />Fail <br />Pass <br />Fail <br />Pass <br />Fail <br />1 <br />8. COMMENTS <br />Are Flow Restrictors Installed? Yes <br />No <br />Yes <br />No <br />Yes <br />No <br />Yes <br />No <br />Describe all results marked "Fail" and each proposed remedy. <br /> <br /> <br /> <br /> <br /> <br />* Mark here if: <br />Flow restrictors interfere with overfill prevention and equipment repairs required.