Laserfiche WebLink
San Joaquin County <br />Environmental Health Department <br />1868 East HazeIton Avenue, Stockton, CA95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 464-0138 Web: www sigoy org/ehd <br />Swimming Pool Complaint Inspection Report <br />Facility Name and Address: BROOKING PARK POOL, 4514 NUGGET AVE, STOCKTON 95207 <br />#7 Pool Deck <br />OBSERVATIONS: Coping is damaged. Fill in with concrete like material. <br />CALCODE DESCRIPTION: An unobstructed 4-foot wide deck of concrete or like material shall be provided and maintained flush with the <br />top of the pool coping. Deck shall extend completely around the pool and shall further extend 4 feet on both sides and to the rear of any <br />diving board, ADA device, or slide. (CBC 3114B) Pool operator shall keep the pool deck well maintained. (CCR 65535) <br />#9 Ladders and Handrails <br />OBSERVATIONS: South-West ladders damaged. Repair to prevent an injury. <br />CAL CODE DESCRIPTION: A means of entry and exit shall be provided at both the shallow and deep end of the pool. Ladders and <br />handrails shall be corrosion resistant and shall be rigidly installed. At least one handrail shall extend from the deck to not less than a point <br />above the top of the lowest step. Handrails shall be installed between 28 to 36 inches above the steps and deck. (CBC 3111B) Pool <br />operator shall keep ladders and handrails well maintained. (CCR 65535) <br />#22 Skimmer Assembly <br />OBSERVATIONS: Weir doors missing and skimmers lack plugs. Provide. <br />CAL CODE DESCRIPTION: Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br />maintained in accordance with manufacturer specifications. (CBC 3136B) <br />#27 Pool Equipment Room <br />OBSERVATIONS: Suction side of pump is loose. Repair. <br />CAL CODE DESCRIPTION: Pool operator shall keep ancillary facilities well maintained. (CCR 65535) All filters, valves, pumps, strainers <br />and equipment shall be readily accessible for repair and replacement. (CBC 3123B) <br />#45 Lifeguard First Aid Equipment <br />OBSERVATIONS: Adequate 1st aid kit not on site. Provide. <br />CAL CODE DESCRIPTION: Public pools with lifeguard services shall have the following safety equipment available in the pool area.. <br />10-person first aid kit, operating telephone, backboard, and head immobilizer. (CCR 65540) <br />OVERALL INSPECTION NOTES AND COMMENTS <br />NOTES <br />Met with Ian Jensen to obtain access to pool area. <br />Observations: <br />1.south-west ladder(s) are broken <br />2.weir doors missing <br />3.equilizer lines not plugged <br />FA0003019 C00041120 SC004 03/15/2016 <br />EHD 36-01 Rev 06/30/15 <br /> <br />Page 2 of 3 Swimming Pool Complaint Inspection Report