Laserfiche WebLink
SAN JOAQUIN i <br />-COUNT Y <br />.,ASeJr, Greotness qrowi here. <br />Environmental Health Department <br />Time In. 10.20 am <br />Time Out: 10:45 am <br /> <br />Swimming Pool Official Inspection Report <br />Name of Facility: AVALON PLACE APARTMENTS Date: 06/19/2019 <br />Address: 198 NORTHGATE DR, MANTECA 95336 <br />Owner/Operator: AVALON OCP II, LLC Telephone: (209) 815-9840 <br />Program Element: 3612- PUBLIC POOL/SPA - ADDITIONAL <br />Inspection Type ROUTINE INSPECTION - Operating Permit <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br />#8 Pool and Deck Lighting <br />OBSERVATIONS: Spa light is out. Replace with new light bulb by today. <br />CALCODE DESCRIPTION: Pools used at night shall be equipped with underwater light fixtures that provide complete illumination of the <br />pool. When a pool is used at night, pool deck and emergency egress areas shall be provided with lighting. If underwater or deck lighting is <br />not operational, the pool operator shall post a sign in 4-inch letters stating "NO USE OF POOL ALLOWED AFTER DARK" and shall <br />secure the pool area and not permit any use of the pool after dark. (3115B) <br />#22 Skimmer Assembly <br />OBSERVATIONS: Float was broken apart. Replace float by today. Corrected on site. <br />0 ring is deteriorating. Replace by today. <br />CALCODE DESCRIPTION: Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br />maintained in accordance with manufacturer specifications. (CBC 3136B) <br />#38 Filter Cleaning and Maintenance <br />OBSERVATIONS: Filter pressure is high. Backwash. Keep psi under 10. Backwash. 2 days. <br />CALCODE DESCRIPTION: All filters shall be maintained in accordance with manufacturer's specifications. (CBC 3123B) Pressure gauge <br />located on the filter shall be marked with the clean startup reading. (CBC 3125B) Each filter vessel shall be provided with valves so that it <br />can be isolated from the recirculation system for repairs and backwashing. (CBC 3128B) <br />OVERALL INSPECTION NOTES AND COMMENTS <br />OBSERVATIONS <br /> <br />Flow rate: 50 gpm Chlorine 9.2 ppm <br /> <br />Cyanuric acid: 30 ppm pH. 7.2 Combined chlorine: .6 ppm <br />NOTES <br />Routine Inspection <br />Influent: 29 <br />Effluent 13 <br />FA0001031 PR0360236 SC001 06/19/2019 <br />EHD 36-01 Rev. 06/30/15 <br /> Page 1 of 2 Swimming Pool OIR <br />Temp: 101.80 ° F <br />1868 E. Hazelton Avenue I Stockton, California 95205 I T 209 468-3420 I F 209 464-0138 I www.sjcehd.com