My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2024
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
1196
>
2300 - Underground Storage Tank Program
>
PR0231430
>
COMPLIANCE INFO_2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/30/2024 10:30:06 AM
Creation date
4/30/2024 10:56:57 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2024
RECORD_ID
PR0231430
PE
2361
FACILITY_ID
FA0000848
FACILITY_NAME
QUIK STOP MARKET #551121
STREET_NUMBER
1196
Direction
W
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
217-410-43
CURRENT_STATUS
01
SITE_LOCATION
1196 W LOUISE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\lsauers1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SYSTEM SET-UP REPORT (Page 1) <br /> SYSTEM SETUP <br /> - - - - - - - - - - - - AUTO TRANSMIT SETTINGS: IN_TANY, SETUP- - - <br /> MAY 16. 2024 9:06 AM VAPOR MONITORING TYPE <br /> GARB ISD AUTO LEAK: ALARM LIMIT <br /> T 1 :Ur-iltaded_Regular <br /> DISABLED <br /> MASS/DENSITYAUTO HIGH WATER LIMIT THERMAL CODE A <br /> DISABLED DISABLED THERMAL METEREFF :.000700 <br /> SYSTEM 1 UNITS AUTO OVERFILL LIMIT TANK DIAMETER 96.00 <br /> U.S.U.S. TANK. PROFILE 4 PTS <br /> SYSTEM LANGUAGE DISABLED FULL VOL : 12000 <br /> ENGLISH FISCAL HEIGHT SECURITY AUTO LOW PRODUCT 72.0 INCH VOL 9999 <br /> SYSTEM DATE TIME FORMAT DISABLED DISABLED 45.0 INCH VOL 6355 <br /> MON DD lYYl HH:MM:SS •1°1 AUTO THEFT LIMIT 24.0 INCH VOL : 2505 <br /> INVENTORY ALARMS UNITS DISABLED <br /> 61U I K. STOP 121 AUTO DELIVERY START <br /> 1196 W.LOUISE AVE. CONFIG: STANDARD DISABLED FLOAT SIZE: 4.0 IN. <br /> MANTEAA. CO. 95336 MAX OR LABEL: VOLUME AUTO DELIVERY END WATER IIIPJINILIPJ 0.000 <br /> 209-239-2957 HIGH PRODUCT: % MAX; DISABLED <br /> OVERFILL MAX AUTO EXTERNAL INPUT ON WATER WARNING : 0.8 <br /> SHIFT TIME 1 3:00 AM DELIV NEEDED: % MAX DISABLED HIGH WATER LIMIT: 1 .0 <br /> SHIFT TIME 2 : DISABLED LOW PRODUCT : VOLUME AUTO EXTERNAL INPUT OFF WATER ALARM FILTER: LOW <br /> SHIFT TIME 3 DISABLED DISABLED <br /> XIFT TIME 4 : DISABLED AUTO SENSOR FUEL ALARM <br /> 1� ALARM REDUCTION DISABLED MAX OR LABEI. <br /> TANK PER TST NEEDED WRN DISABLED AUTO SENSOR WATER ALARM VOLUME 12000 <br /> DISABLED DISABLED <br /> TANK ANN TST NEEDED WRN AUTO SENSOR OUT ALARM HIGH PRODUCT <br /> DISABLED DISABLED % MAX 95.0 <br /> (GALLONS) 11400 <br /> LINE RE-ENABLE METHOD <br /> PASS LINE TEST OVERFILL LIMIT <br /> MA: : 90.0 <br /> LINE PER TST NEEDED WRN RECEIVER SETUP: 10800 <br /> DISABLED <br /> LINE ANN TST NEEDED WRN DELIVERY LIMIT <br /> DISABLED % MAX : 10.0 <br /> U I :RHDIENT (GALLONS') 1'200 <br /> PRINT TC' VOLUMES COMMUNICATIONS �ETUP <br /> ENABLED - - - - - - - - - - - - RCVF. TYPE: COMPUTER LOW PRODUCT <br /> FORT NO: 3 VOLUME : 736 <br /> TEMP COMPENSATION RETRY NO: 3 <br /> VALUE (DEG F is 60.0 FORT SETTINGS: RETRY DELAY: 3 LEAK ALARM LIMIT: 99 <br /> STICK HEIGHT OFFSET CONFIRMATIiON REPORT: OFF SUDDEN LOSS LIMIT: 99 <br /> DISABLED COMM BOARD 1 (S-SAT : TANK TILT 2.38 <br /> ULLAGE: 90% BAUD RATE 9600 PROBE OFFSET 0.00 <br /> PARITY NONE <br /> H-PROTOCOL DATH FORMAT STOP BIT 2 STOP <br /> HEIGHT DATA LENGTH: 8 DATA SIPHON MANIFOLDED TANKS <br /> DAYLIGHT SAVING TIME RS-232 SECURITY TO: NONE <br /> ENABLED CODE : DISABLED LINE MANIFOLDED TANKS <br /> START DATE DTR NORMAL STATE: HIGH TO: NONE <br /> APR WEER: I SUN <br /> START TIME COMM BOARD 2 (RS-232) <br /> 2:00 AM BAUD RATE 1200 LEAH: MIN PERIODIC: 0% <br /> END DATE PARITY ODD AUTO DIAL TIME SETUP: 0 <br /> OCT WEER: 6 SUN STOP BIT 1 STOP PERIODIC TEST TYPE <br /> END TIME DATA LENGTH: 7 DATA STANDARD <br /> 2:00 AM RS-232 SECURITY D 1 :RADIENT <br /> CODE : DISABLED DIAL ON DATE PERIODIC TEST FAIL <br /> RE-DIRECT LOCAL PRINTOUT APR 23, 2009 ALARM DISABLED <br /> DISABLED COMM BOARD : 3 (EDIM 7 DIAL TIME : DISABLED <br /> RS-232 SECURITY RECEIVER REPORTS: GROSS TEST FAIL <br /> EURO PROTOCOL PREFIX CODE DISABLED ALARM DISABLED <br /> S <br /> PER TEST AVERAGING: OFF <br /> TANK TEST NOTIFY: OFF <br /> SYSTEM SECURITY <br /> CODE : 000000 TNK TST SIPHON BREA1::OFF <br /> MAINTENANCE HISTORY DELIVERY DELAY I MIN <br /> IiISABLED PUMP THRESHOLD 10.00% <br /> TANK CHART SECURITY <br /> DISABLED <br /> RS-232 END OF MESSAGE <br /> DISABLED <br /> CUSTOM ALARMS <br /> DISABLED AUTO DIAL ALARM SETUP, <br /> SERVICE NOTICE D 1 :RADIENT <br /> DISABLED - NO ALARM ASSIGNMENT'S: - <br /> ISO 3166 COUNTRY <br /> CODE: <br /> 0 mu WAM Engineering,Inc. <br />