Laserfiche WebLink
A dOAQU1N Environmental Health Department <br /> COUNTY— <br /> EffW- <br /> CP22 - UST FULL Inspection Report <br /> Facility Name: Facility Address: Date: <br /> STOP N SHOP 1 1856 W COUNTRY CLUB BLVD STOCKTON June 03 2024 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> http://cers.calepa.ca.gov/, and upload the required documents. <br /> This is a repeat violation (Class 2) Violation. <br /> 56 CA Code of Regulations 2716(a-e)2030013-DO inspections completed at least every 30 days and meet all <br /> requirements(TCR 12). <br /> OBSERVATION:The designated operator failed to check and note all required items on the visual inspection reports. <br /> The incorrect and missing information included the following from the inspection reports: <br /> -Section 9 not complete from 6/30/2023 <br /> -Section 8 not complete from 6/30/2023 <br /> -Section 6 not complete from 6/30/2023 <br /> REGULATION GUIDANCE: During the visual inspection,the designated operator shall check that all required testing <br /> and maintenance for the UST system have been completed and shall check all required items on the report. <br /> CORRECTIVE ACTION: Ensure that designated operators performing visual inspections at this facility are including all <br /> of the required information on the reports. <br /> This is a repeat violation (Class 2) Violation. <br /> 59 CA Code of Regulations 2712(b)(1-2)2030001 - Records of release detection monitoring and maintenance properly <br /> maintained (TCR 9d). <br /> OBSERVATION: Maintenance and monitoring records for the last three years were not found on site. <br /> - Monitoring Certification Report from 6/16/2023 <br /> -Overfill Report from 4/1/2021 <br /> REGULATION GUIDANCE:These records shall be maintained on site for at least three years. Monitoring records <br /> include: (1)date and time of all monitoring or sampling; (2)monitoring equipment calibration and maintenance records; <br /> (3)results of any visual observations; (4)results of sample analysis performed a lab or in the field; (5)logs of all <br /> readings of gauges or other monitoring equipment, ground water elevations, or other test results; (6)results of <br /> inventory readings and reconciliations. <br /> CORRECTIVE ACTION: Immediately locate and maintain all missing maintenance and monitoring records for the last <br /> three years on site. Submit copies of any missing work orders and alarm records to the EHD. <br /> This is a repeat violation (Class 2) Violation. <br /> 68 CA Code of Regulations 2712(1), 2634(e)2030046-A current UST Response Plan has been submitted. <br /> OBSERVATION:An approved copy of the response plan was not available for inspection. <br /> REGULATION GUIDANCE:A copy of this plan shall be accessible on site at all times. <br /> CORRECTIVE ACTION: Immediately locate and retain a copy on site. <br /> This is a repeat violation (Class 2) Violation. <br /> 69 CA Code of Regulations 2712(1)2030033-A current UST monitoring plan has been submitted and is readily <br /> accessible at the facility. <br /> FA0001909 PR0231069 SCO01 06/03/2024 <br /> EHD Rev.12/06/2021 Page 8 of 10 CP22-UST FULL OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />