My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2024
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
1901
>
2300 - Underground Storage Tank Program
>
PR0231092
>
COMPLIANCE INFO_2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/16/2024 11:56:19 AM
Creation date
5/13/2024 10:32:57 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2024
RECORD_ID
PR0231092
PE
2361 - UST FACILITY
FACILITY_ID
FA0001946
FACILITY_NAME
El Dorado Food Mart
STREET_NUMBER
1901
Direction
S
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
16508019
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
1901 S EL DORADO ST STOCKTON 95206
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A AAQUI Environmental Health Department <br /> COUNTY <br /> CP22 - UST FULL Inspection Report <br /> Facility Name: Facility Address: Date: <br /> EI Dorado Food Mart 1901 S EL DORADO ST STOCKTON August 14, 2024 <br /> 17 CA Code of Regulations 2030051-0.1 gph piping test conducted on SW gravity systems every 24 mths and after piping ❑OUT ❑R ❑COS <br /> 2643(e),2661(f) repair(TCR 9d) <br /> 18 CA Code of Regulations 2030029-Tank lining inspected w/in 10 years of lining,every 5 years after, cert submitted to CUPA ❑OUT ❑R ❑COS <br /> 2663, 2712(b)(6) (TCR 9c) <br /> 19 CA Code of Regulations 2010005-ELD testing results sent to the board and the CUPA within 60 days of completion of the ❑OUT ❑R ❑COS <br /> 2644.1(a)(5) test <br /> 20 CA Code of Regulations 2030056-SIR Report submitted to the CUPA every 12 months ❑OUT ❑R ❑COS <br /> 2646.10) <br /> 21 CA Code of Regulations 2030064-CUPA was notified within 48 hours prior to testing ❑OUT ❑R ❑COS <br /> 2637,2638(e),2643(g) <br /> 22 CA Code of Regulations 2030068-Initial or triennial ELD testing conducted on UST system 1000'of public well ❑OUT ❑R ❑COS <br /> 2640(e),2644.1 <br /> 23 CA Code of Regulations 2060001-As-built plans for new installations and/or with the permit application have been ❑OUT ❑R ❑COS <br /> 2635(e)(8) submitted <br /> 24 CA Code of Regulations 2030003-Leak detection system maintains continuous monitoring that activates an audible and ❑OUT ❑R ❑COS <br /> 2632(c),2634(d), visual alarm <br /> 2636(f) <br /> 25 CA Code of Regulations 2030016-Annular space of USTs are continuously monitored with an audible and visual alarm ❑OUT ❑R ❑COS <br /> 2631(g),2632(c)(2) system(TCR 9d) <br /> 26 CA Code of Regulations 2030017-Piping out of UDC is fail-safe/shut down, UDC leak shuts off pump/flow,or tightness ❑OUT ❑R ❑COS <br /> 2636(f)(4) test(TCR 9d) <br /> 27 CA Code of Regulations 2030018-DW press piping is monitored with an audible/visual alarm or stops flow at UDC(TCR ❑OUT ❑R ❑COS <br /> 2666(b)(2),2636(f)(1) 9d) <br /> 28 CA Code of Regulations 2030043-Leak detection equipment properly installed,calibrated,operated,and maintained(TCR ❑OUT ❑R ❑COS <br /> 2638(a),26410) 9d) <br /> 29 CA Health and Safety 2060005-UST system constructed with a mon system capable of detecting entry into secondary ❑OUT ❑R ❑COS <br /> Code 2636(a)(1), containment <br /> 25291(b) <br /> 30 CA Code of Regulations 2060015-Leak detection equipment located so leak is detected at the earliest possible opportunity ❑OUT ❑R ❑COS <br /> 2630(d),2641(a) (TCR 9d) <br /> 31 CA Health and Safety 2030062-Leak detection equipment has not been tampered with or disabled(TCR 9d) ❑OUT ❑R ❑COS <br /> Code 25299(a)(9) <br /> 32 CA Code of Regulations 2030075-E Gen System LLD detects 3 gph leak&restricts/shuts off flow or activates and/vis ❑OUT ❑R ❑COS <br /> 2636(f),2666(c), alarm(TCR 9d) <br /> 2666(f) <br /> 33 CA Health and Safety 2060022-System has a mon system capable of detecting entry of haz sub or water into ❑OUT ❑R ❑COS <br /> Code 25290.2(d) secondary containment <br /> 34 CA Code of Regulations 2030034-Tag/sticker on affixed monitoring equipment being certified,repaired,or replaced ❑OUT ❑R ❑COS <br /> 2638(f),26410) <br /> 35 CA Health and Safety 2030065-Interstitial space of the UST is under constant VPH monitoring(TCR 9d) ❑OUT ❑R ❑COS <br /> Code 25290.1(a) <br /> 36 CA Health and Safety 2060023-System has a mon system that can detect entry of haz sub liquid/vapor,or water into ❑OUT ❑R ❑COS <br /> Code 25290.1(d) sec contain <br /> 37 CA Code of Regulations 2030009-Cathodic protection is installed/maintained as required,including required documentation ❑OUT ❑R ❑COS <br /> 2635,2636(b),2662, (TCR 9c) <br /> 2712 <br /> 38 CA Code of Regulations 2030005-SW tank continuous in tank leak detection test is functioning properly(TCR 9d) ❑OUT ❑R ❑COS <br /> 2643(b)(3) <br /> 39 CA Code of Regulations 2030006-Monthly 0.2 gph ATG test is being conducted and copies of test results are available ❑OUT ❑R ❑COS <br /> 2643(b)(1) (TCR 9d) <br /> 40 CA Health and Safety 2060002-SW UST system has monitoring system capable of detecting releases(TCR 9d) ❑OUT ❑R ❑COS <br /> Code <br /> FA0001946 PR0231092 SCO01 08/14/2024 <br /> EHD Rev.12/06/2021 Page 2 of 5 CP22-UST FULL OR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.