My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2024
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HUNTER
>
642
>
2300 - Underground Storage Tank Program
>
PR0231148
>
COMPLIANCE INFO_2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/4/2024 3:13:00 PM
Creation date
5/13/2024 11:02:44 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2024
RECORD_ID
PR0231148
PE
2361
FACILITY_ID
FA0000799
FACILITY_NAME
Nashir Hunter Inc.
STREET_NUMBER
642
Direction
N
STREET_NAME
HUNTER
STREET_TYPE
ST
City
STOCKTON
Zip
95202
APN
13906035
CURRENT_STATUS
01
SITE_LOCATION
642 N HUNTER ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\lsauers1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A dOAQU1N Environmental Health Department <br /> CQLJIVTY AMENDED <br /> 6/3/2024 <br /> CP22 - UST FULL Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Nashir Hunter Inc. 642 N HUNTER ST STOCKTON May 29 2024 <br /> 86 CA Code of Regulations 2060024-UST system is made of or lined with materials that are compatible with the substance ❑OUT ❑R ❑COS <br /> 2631.1,2660(m) stored. <br /> 87 CA Code of Regulations 2060021-Striker plate installed and positioned correctly. ❑OUT ❑R ❑COS <br /> 2631(c),2662(d) <br /> 88 CA Code of Regulations 2060007-Primary and secondary containment designed and constructed to an engineering ❑OUT ❑R ❑COS <br /> 2631(b&d),2666(b&e) specification. <br /> 89 CA Health and Safety 2060008-Enhanced leak detection testing performed before the tank is placed in use ❑OUT ❑R ❑COS <br /> Code 25290.10) <br /> 90 CA Code of Regulations 2060029-SW piping has been upgraded to continuously monitored DW piping when replacement ❑OUT ❑R ❑COS <br /> 2666(b)(2) or repair needed <br /> 91 CA Health and Safety 2010-Administration/Documentation-General ❑OUT ❑R ❑COS <br /> Code 25291(e) <br /> 92 2015-Administrative/Documentation-General Local Ordinance ❑OUT ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 30 CA Code of Regulations 2630(d),2641(a)2060015-Leak detection equipment located so leak is detected at the <br /> earliest possible opportunity(TCR 9d). <br /> OBSERVATION:The 87 sensor was raised approximately 7 inches off the lowest point of the sump and not located to <br /> detect a leak at the earliest opportunity. <br /> REGULATION GUIDANCE: Monitoring equipment shall be maintained to be able to detect a leak at the earliest <br /> possible opportunity. <br /> CORRECTIVE ACTION: The sensor was relocated to the lowest point of the sump by the service technician. Ensure <br /> that all monitoring equipment is maintained and located to detect a leak at the earliest opportunity. <br /> This is (Class 1)Violation. <br /> 31 CA Health and Safety Code 25299(a)(9)2030062-Leak detection equipment has not been tampered with or disabled <br /> (TCR 9d). <br /> OBSERVATION:The 87 STP sump was observed with approximately 3.5 inches of liquid inside along with the sensor <br /> approximately 7 inches off the lowest point of the sump and not located to detect a leak at the earliest opportunity. <br /> REGULATION GUIDANCE:An operator of an underground storage tank system shall not allow tampering with or <br /> otherwise disabling automatic leak detection devices or alarms. <br /> CORRECTIVE ACTION: Immediately place the sensor at the lowest point of the sump and maintain the monitoring <br /> system in proper operating conditions at all times. <br /> This is (Class 1)Violation. <br /> 53 CA Health and Safety Code 25292.2; CCR 2711(a)(11)2010007-Submitted/maintained current Cert of Financial <br /> Responsibility/mech of financial assurance(TCR 11). <br /> OBSERVATION: Current financial responsibility documents were not found on site. <br /> REGULATION GUIDANCE:A copy of current financial responsibility documents are required to be maintained on site. <br /> CORRECTIVE ACTION: Immediately obtain a copy of the facility's financial responsibility documents and maintain a <br /> copy on site. <br /> FA0000799 PR0231148 SCO01 05/29/2024 <br /> EHD Rev.12/06/2021 Page 5 of 8 CP22-UST FULL OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page